23 On-the-fly marking
There is a distance of 5mm between the trigger detecting position and the marking data.
(1)
(2)
(3)
(4)
(6)
(7)
(5)
5mm
(1) Trigger detecting position
(2) Trigger sensor
(3) Marking start position on the workpiece (lasing start boundary)
(4) Workpiece
(5) Workpiece reference boundary
(6) Moving direction
(7) Marking field
Remarks
• The workpiece reference boundary is displayed in the marking image editor. The default
position is the center of the marking field.
• It is possible to set the workpiece reference boundary outside the marking field.
• To fine-tune the marking position, change the position of the workpiece reference
boundary or the marking data.
‒ To correct the marking start position backward, adjust the workpiece reference
boundary to downstream direction.
‒ To correct the marking start position forward, adjust the workpiece reference
boundary to upstream direction.
“Lasing start boundary [mm]”
For “Lasing start boundary [mm]”, specify the boundary position in the marking field. When
the workpiece reaches this boundary, the lasing process starts.
The boundary is measured from the center of the marking field. A positive value indicates
an upstream position (before the center of the marking field). A negative value indicates a
downstream position (after the center of the marking field).
ME-NAVIS2-OP-1
245