10-C-8
If the DHLC card is assigned
• As both the XDP mode and the Parallel Connect mode are OFF in the default
setting of all ports of the DHLC card, you cannot execute any assignment for the
XDP port (1 to 8). (See <1> in the screen below.)
• To assign the DN to the XDP port, follow the following procedure:
1) Assign the DN for paired extension port (9 to16). (See <2> in the screen
above.)
2) Select “Yes” for the XDP mode in the “Extension-Station (1/4)” screen for
paired extension port (see 10-G-1.00).
3) Assign the DN for the XDP port in this screen.
• You cannot remove the paired extension port while assigning XDP mode to “Yes”.
• A DSS Console cannot be assigned to the port while XDP mode is “Yes”.
• If “Yes” is selected for the Parallel Connect mode in the “Extension-Station (1/4)”
screen (see 10-G-1.00), DN cannot be assigned for the XDP ports.
Configuration - DN Assignment
| OFL | PRG | SCR | DIR
------------------------------------------------------------------------------------ + ----- + ----- + ----- + -----
DN Assignment (1/2)
+ ---------------------------------------------------------------------------------------------------------------- +
| Slot |
PLC
|
HLC
|
SLC
|
DLC
|
DHLC
|
| No. |
101
|
102
|
103
|
104
|
105
|
| ------ + ------------------ + ----------------- + ------------------- + ------------------ + ------------------- |
| Port |
DN
|
DN
|
DN
|
DN
|
DN
|
| ------ + ------------------ + ----------------- + ------------------- + ------------------ + ------------------- |
| 1| 9 | 100
| -
| 108
| -
| 116
| -
| 124 | 132
| -
| 140
|
| 2| 10 | 101
| -
| 109
| -
| 117
| -
| 125 | 133
| -
| 141
|
| 3| 11 | 102
| -
| 110
| -
| 118
| -
| 126 | 134
| -
| 142
|
| 4| 12 | 103
| -
| 111
| -
| 119
| -
| 127 | 135
| -
| 143
|
| 5| 13 | 104
| -
| 112
| -
| 120
| -
| 128 | 136
| -
| 144
|
| 6| 14 | 105
| -
| 113
| -
| 121
| -
| 129 | 137
| -
| 145
|
| 7| 15 | 106
| -
| 114
| -
| 122
| -
| 130 | 138
| -
| 146
|
| 8| 16 | 107
| -
| 115
| -
| 123
| -
| 131 | 139
| -
| 147
|
+ ---------------------------------------------------------------------------------------------------------------- +
<1> DN assignment for XDP port (1 to 8)
<2> DN assignment for extension port (9 to 16)
1 COMMON 2
3
4
5
6 HRD CPY 7
8
COMMON (SHOW LV, CHG LV, INS, OUS, REMOVE, EXIT) and HRD CPY keys
are available in this setting screen.
For operation, refer to Section 8-I “Operation of Function Keys”.
Function
The following functions appear on the function line of this setting screen.
Содержание KX-TD500
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...Section 1 System Outline ...
Страница 10: ......
Страница 20: ......
Страница 26: ......
Страница 32: ......
Страница 36: ......
Страница 51: ...Section 2 Installation ...
Страница 52: ......
Страница 56: ......
Страница 78: ......
Страница 160: ......
Страница 173: ...Section 3 System Features and Operation ...
Страница 174: ......
Страница 178: ......
Страница 180: ......
Страница 208: ......
Страница 218: ......
Страница 256: ......
Страница 260: ......
Страница 361: ...Section 4 Station Features and Operation Proprietary Integrated Telephone System PITS ...
Страница 362: ......
Страница 376: ...4 A 10 Programmable Feature buttons F1 F2 F3 TRANSFER PF01 PF02 PF03 ...
Страница 434: ......
Страница 462: ......
Страница 492: ......
Страница 516: ......
Страница 536: ......
Страница 576: ......
Страница 577: ...Section 5 Station Features and Operation Single Line Telephone SLT ...
Страница 578: ......
Страница 602: ......
Страница 642: ......
Страница 656: ......
Страница 675: ...Section 6 Station Features and Operation Attendant Console ATT ...
Страница 676: ......
Страница 680: ......
Страница 686: ......
Страница 688: ......
Страница 728: ......
Страница 746: ......
Страница 750: ......
Страница 768: ......
Страница 782: ......
Страница 814: ......
Страница 816: ......
Страница 817: ...Section 7 Manual Vol 2 Overview ...
Страница 818: ......
Страница 820: ......
Страница 822: ......
Страница 833: ...Section 8 Preparation for Programming and Maintenance VT220 and Compatibles ...
Страница 834: ......
Страница 850: ......
Страница 860: ......
Страница 864: ......
Страница 866: ......
Страница 868: ......
Страница 870: ......
Страница 899: ...Section 9 Preparation for Programming and Maintenance Dumb Type Terminal ...
Страница 900: ......
Страница 914: ......
Страница 920: ......
Страница 930: ......
Страница 931: ...Section 10 System Programming VT220 and Compatibles ...
Страница 932: ......
Страница 936: ......
Страница 938: ......
Страница 940: ......
Страница 1024: ......
Страница 1090: ......
Страница 1117: ...Section 11 System Programming Dumb Type Terminal ...
Страница 1118: ......
Страница 1122: ......
Страница 1124: ......
Страница 1260: ......
Страница 1269: ...Section 12 System Programming Proprietary Integrated Telephone System PITS ...
Страница 1270: ......
Страница 1272: ......
Страница 1274: ......
Страница 1302: ......
Страница 1303: ...Section 13 Station Programming Proprietary Integrated Telephone System PITS ...
Страница 1304: ......
Страница 1306: ......
Страница 1308: ......
Страница 1368: ......
Страница 1369: ...Section 14 Station Programming Attendant Console ...
Страница 1370: ......
Страница 1372: ......
Страница 1378: ......
Страница 1392: ......
Страница 1394: ......
Страница 1395: ...Section 15 Maintenance VT220 and Compatibles ...
Страница 1396: ......
Страница 1400: ......
Страница 1402: ......
Страница 1406: ......
Страница 1418: ......
Страница 1476: ......
Страница 1495: ...Section 16 Maintenance Dumb Type Terminal ...
Страница 1496: ......
Страница 1500: ......
Страница 1508: ......
Страница 1520: ......
Страница 1536: ......
Страница 1540: ......
Страница 1541: ...Section 17 Backup Utility On Site ...
Страница 1542: ......
Страница 1544: ......
Страница 1546: ......
Страница 1556: ......
Страница 1558: ......
Страница 1559: ...Section 18 Backup Utility Remote Location ...
Страница 1560: ......
Страница 1562: ......
Страница 1564: ......
Страница 1570: ......
Страница 1571: ...Section 19 Abbreviations ...
Страница 1572: ......