5.4.3 Operation during running
(1) Check again if the settings of switches in master and slave are correct or not.
・
Unit No. of master set to “00”, Unit No. of slave is set to the registered No.
・
Communication channels of master and slave are same.
・
MODE switch No.1 in master and slave are set to ON.
No.2: serial communication selection (RS232C/RS485), or data holding (available/not available)
No.3
~
8: set baud rate, data length and parity according to the connected equipment.
(2) Set operating mode switch in master and slave to <RUN>.
(3) Turn power supply of master and slave on.
Master
Unit No.:00
Slave
Unit No.: Registered No.
No.1:ON Serial communication selection, baud rate, data length,
parity should be set according to connected equipment.
Same communication channel
5-17