Procedures for communication test
(1) Set all switches as above.
(2) Power supply of master and slave on.
Slave
Master
Lighting Lighting
Lighting
(3) Press <ENTER> switch to start communication test.
LED is blinking as level meter.
In the actual system, use with the field intensity that indicates a. or b.
a. When radio wave condition is good.
Master
Slave
Lighting Blinking
Blinking Blinking Blinking
(3 LEDs are blinking.)
b. When radio wave condition is not bad.
Master
Slave
(2 LEDs are blinking.)
Lighting Blinking
Blinking Blinking
c. When it is communicationg but radio wave condition is weak.
Master
Slave
Lighting Blinking
Blinking
(1 LED is blinking.)
d. When an radio wave does not reach at all.
Master
Slave
(4) Press <ENTER> again to stop communication test.
Note: When communication doesn’t work well even if master and slave are near, the below
Lighting Lighting
Lighting Blinking
causes are supposed. Check them and take communication test again.
Causes
Troubleshooting
Power supply of master is OFF.
Turn the power supply of master on.
Settings of master or slave are not correct. Check the settings.
After setting master and slave, it doesn’t
turn power supply on again.
Turn the power supply on again.
or
Change operating mode switch.
(TEST
→
RUN
→
TEST)
Another wireless unit is using the same
frequency.
Change communication channel.
Antenna is removed.
Connect antenna surely.
6-4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Содержание KR20
Страница 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 4: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 10: ...1 6 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 117: ...9 1 Chapter 9 Specifications Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...