6.3.5 Field intensity monitor
You can check vacancy of communication channel by using wireless unit as simplified field
intensity monitor. When signal is received, the communication channel is using. If using another
channel, you can avoid interference. We recommend checking it before mounting.
(1) Select “Utility” -> “Field intensity monitor” in menu.
(2) Dialog to select monitor conditions is displayed, input conditions.
Frequency
Select one of below 2 method (Scan specified channel, Scan all channels.) In case of selecting
scan specified channel continuously.
In case of selecting scan all channel, it is possible to monitor with changing 00-4B
Monitoring time
Select “Keep monitoring” or “Monitoring in specified time”.
Input with the range of 1 to 32767 minutes for time period.
In both ways, it can stop monitoring.
(3) When the below dialog is displayed, click “OK”.
Field intensity level during monitoring is displayed.
Present value is the value of last monitoring, peak value is the maximum value during monitoring.
When stop monitoring, click “Stop”. Monitoring result until the time is displayed.
Communication channel is vacant when feild intensity level is low. (Around 16 means vacant.)
6-14
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Содержание KR20
Страница 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 4: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 10: ...1 6 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 117: ...9 1 Chapter 9 Specifications Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...