6.2 Test functions of main unit
6.2.1 Communication test
You can check if it can communicate between master and slave or not beforehand.
Slave’s level meter shows the field intensity, it is convenient when examining the place to mount
wireless units. Slave registration is not necessary for this function.
Master’s setting
Operating mode switch
Be sure to set to <TEST>.
Communication channel
Select from “00
~
F5”. *1
Unit No. switch
Be sure to set to “00”.
At factory setting, Unit No, is set to “00”.
Any settings
MODE switch
Refer to <3.2.4 Setting of MODE switch>
Slave’s setting
Operating mode switch
Be sure to set to <TEST>.
Communication channel
Select same channel as master.
Be sure to set to “01”.
Unit No. switch
At factory setting, Unit No, is set to “00”.
Be sure tp set No.9 to OFF. Except it, any settings
are OK.
MODE switch
Refer to <3.2.4 Setting of MODE switch>
*1 Do not use communication channel of 4C
~
5F, 81
~
8F, A6
~
AF, BB
~
CF, D7
~
DF, EA
~
EF
and F6
~
FF. Refer to Chapter 9 “Attachment Using frequency”.
6-3