4.2 Register slave by main unit
4.2.1 Procedures for slave registration
Setting of master
Operating mode switch
Be sure to set to “SET”.
Communication channel
Select from “00
~
4B” *1
Unit No. switch
Be sure to set to “00”.
At factory setting, Unit No. is set to “00”.
MODE switch
Any settings
Refer to <3.2.4 Setting of MODE switch>
*1:Communication channel can be set to fixed channel(00
~
4Bch). If it is set to group channel,
error is occurred.
And if it is set to channel used in the other communication, error might be occurred. We
recommend you to check vacant channel beforehand by field intensity monitor.
Setting of slave
Operation mode switch
Be sure to set to “SET”.
Communication channel
Select same channel as master
Unit No. switch
Set to “01
~
99”.
At factory setting, Unit No. is set to “00”.
MODE switch
Be sure to set No.9 to OFF. Except it, any settings
are OK. Refer to <3.2.4 Setting of MODE switch>
4-3