MODE switch
Setting of 1:N topology is Available/Not available, Change of RS232C or RS485, Data holding
Available/Not available, Setting of communication conditions are set.
Change it by precision slotted screwdriver carefully.
SW No.
Function
ON/
OFF
Contents
OFF
Not available (1:1 topology)
1
Setting of 1:N topology by setting
tool
Available/Not available
ON
Available
(1:1 topology with repeaters and 1:N
topology)
OFF
RS232C
RS485 type
Select of serial
communication
ON
RS485
OFF
Not available (Turn off output when
communication error occurs)
2
I/O type
Data holding
ON
Available (Hold output when
communication error occurs)
3
4
5
Transmission speed
-
OFF
7bit
6
Data
Length
ON
8bit
OFF
No
parity
7
Parity
ON
Available
OFF
Even
8
Parity
Odd/Even
ON
Odd
OFF
Function not available (generally)
9
Function
ON
Function
available
OFF
Not available of registration overwriting
0
Permission of registration
overwriting
ON
Permission of registration overwriting
※
Stop bit is fixed with 1 bit.
Factory setting
■
RS485 type
1:N topology
setting by
setting tool
Selection of
serial
communication
Transmission
speed
Data
length
Parity
Function
Registration
overwriting
Not available
RS232C
19200bit/s
8bit
Odd
Not
available
Not available
※
Stop bit is fixed with 1 bit.
2-9
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Содержание KR20
Страница 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 4: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 10: ...1 6 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 117: ...9 1 Chapter 9 Specifications Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...