Note: If the previous slave registered with the Unit No. is left in the same communication
area and turn the power supply on, it causes malfunction of communication system.
Turn the power supply off or change Unit No. When it is used with another Unit No.,
initialize before using.
Reference:
<5.9 Initialization>
4.2.3 Change Unit No. of slave
Once slave is registered to master, the slave doesn’t work as another Unit No. even if
changing Unit No. switch.
In case of changing to another vacant Unit No., you can register slave by main unit (Refer to
<4.2.1 Procedures for slave registration>). At that time, master deletes registered information of
slaves automatically.
Example) After registration of slave (slave1) “01” at master”00”, if the slave Unit No. is changed to
“05” and the slave is registered again, master deletes “01” and the slave (slave1) is registered as
“05”. (When there are mistakes at setting of slave Unit No.)
Before changing Unit No.
After changing Unit No.
Slave registration info. in Master
Slave registration info. in Master
Unit No.
Slave name
Unit No.
Slave name
01
02
03
04
05
…
99
slave 1
slave 2
slave 3
(vacant)
(vacant)
…
(vacant)
01
02
03
04
05
…
99
(vacant)
←
deleted and vacant
slave 2
slave 3
(vacant)
slave 1
←
change 01 to 05
…
(vacant)
※
Slave name is set by setting tool.
Note: If Unit No. to change is not vacant and other has been registered, it is error.
Register again with another Unit No. or overwrite registration.
Reference
:
<4.2.1 Procedures for slave registration > <4.2.2 Overwrite registration>
4.2.4 Delete slave registration individually
Main unit doesn’t have a function that slave registration information in master individually is
deleted.
In order to delete individually, delete slave in registration list by setting tool.
It is no problem because there is no influence by information of slave that is not used in master.
Note: When using slave to be deleted the registration, initialize before using.
Reference
:
About Initialization <5.9 Initialization>
About registration list <Help in setting tool (Configurator KR)>
4-6
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Содержание KR20
Страница 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 4: ...Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 10: ...1 6 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...
Страница 117: ...9 1 Chapter 9 Specifications Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net ...