(2) Select “Utility” -> “Communication test” in menu.
(3) Dialog to select test conditions is displayed, input conditions of communication test.
Slave Unit No.
Select slave for communication test. Slaves without routing setting and slave registration cannot
be tested.
Data size
Set data size for communication test.
Select from 8,16,32,64,128,256,512,1024,2016 bytes.
Command sending times
Set the times of serial sending the data.
Input with the range of 1 to 255.
Sending interval
Set the interval of sending data continuously.
It shows the time from returning response to computer to sending next data.
Input with the range of 0 (at once) to 255 minutes.
Timeout period (Round trip)
It shows the period to get response from slave after sending data from computer.
Input with the range of 1 to 999 seconds. Normally, there is no problem with default
(4) When the below dialog is displayed, click ‘OK’.
Below dialog is displayed during data communication.
It indicates sending numbers(all) and present sending numbers.
6-12