Read out the ON or OFF condition of input terminal 0 (switch) of slave1
・
Send command from upper computer
%01#RCSX00001D(CR)
※
Hereinafter (CR) shows CR code.
・
Response from slave 1
%01$RC021(CR)
・・・
Input 0 is set to OFF
●
Set output terminal 0 (flasher) of slave3 to ON
・
Send command from upper computer
%03#WCSY000012A(CR)
・
Response from slave 3
%03$WC16(CR)
・・・
White OK
Computer
Slave 01
Master 00
%01#RCSX00001D(CR)
→
%01#RCSX00001D(CR)
%01$RC021(CR)
←
%01$RC021(CR)
Switch
%03#WCSY000012A(CR)
●
Send MEWTOCOL command to PLC4
・
Send command from upper computer
%04#RT04 (CR)
・
Response from PLC4
%04$RT
・・・
(CR)
Slave 02
Master 00
%04#RT04 (CR)
→
%04#RT04 (CR)
←
%04$RT
・・・
(CR)
%04#RT04 (CR)
Computer
PLC 04 (MEWTOCOL)
%04$RT
・・・
(CR)
%04$RT
・・・
(CR)
→
←
%03$WC16(CR)
%03#WCSY000012A(CR)
→
uter
Slave 03
Slave 01
(Repeater)
Drive circuit
Comp
→
←
%03$WC16(CR)
%03$WC16(CR)
Master 00
%03#WCSY000012A(CR)
→
Flasher
5-32
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]