manualshive.com logo in svg
background image

Documentation Number –p/n 8577R1 ZP9D-115RM-LR-0812qsg

 

 

C

C

h

h

e

e

c

c

k

k

 

 

f

f

o

o

r

r

 

 

A

A

l

l

l

l

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

 

 

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

 

 

 

ZLINX™ ZP9D-115RM-LR 

 

This Quick Start Guide 

 

CD with ZLINX™ Manager Software and manual 

 

Antenna 

 

Terminal Block (Attached) 

 

Additional items required but not included: 

o

 

10 – 48 VDC / 18 – 30 VAC) 6.0 W Power Supply  

o

 

Serial Cable 

 

 

Special Precautions for UL and UL Class I DIV 2 
 

 
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF 

COMPONENTS MAY INPAIR SUITABILITY FOR CLASS I, 
DIVISION 2 

 
WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS 

LOCATIONS, TURN OFF POWER BEFORE REPLACING 
ANTENNA 

 
WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT 

EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF 
OR THE AREA IS KNOWN TO BE NONHAZARDOUS 

 
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, 

DIVISION 2, GROUPS A, B, C, AND D OR UNCLASSIFIED 
LOCATIONS 

 
Maximum Ambient Air Temperature 85°C (185°F) 

 
Wiring Terminals: 

Copper Wire Only 
One Conductor per Terminal 

Wire Range 28 to 16 AWG 
Tightening Torque 1.7 lb-in 

Temperature Rating of Field Wiring – 105° C (221° F) sized 
for 60° C (140°F) ampacity.    

 
 

 

Radio Modem Options Screen 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Quick Start 

Guide 

ZP9D-115RM-LR 

Zlinx™ Radio 

Modem 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

Z

Z

l

l

i

i

n

n

x

x

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

 

 

 

 

Insert the CD into your CD ROM Drive. The Zlinx™ 

Manager Install Wizard should start. Follow the on-
screen instructions to install the software.  

 

If auto run is disabled, locate the Zlinx Manager file on 

the CD and double click it. The Install Wizard should 
start. Follow the on-screen instructions.  

2

1

 

 

S

S

t

t

a

a

r

r

t

t

 

 

t

t

h

h

e

e

 

 

Z

Z

l

l

i

i

n

n

x

x

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

 

 

 

Start the Zlinx™ Manager Software.  

 

Click the Radio Modem Button. 

 

Click the Radio Modem Configuration Button.  

o

 

Select your COM port and configure it for 9600 baud, 
Data Bits: 8, Parity: None, Stop Bit: 1.  

 

Click the Connect Button. 

 

When the software locates the Radio Modem, the Basic 

Modem Settings Screen will be displayed. This screen 
will display the Model Number, Function Set Type, 
Firmware Version, Network Identifier, Destination 
Address, Baud Rate, and Parity.  

 

If the settings where changed from the default, Auto 

Modem Search can be used to locate the modem. The 
Auto Search will use a sequence of COM Ports and 
settings until a response is received. If there is still no 
response, double check the power supply and serial 
cable. Also, make sure that no other devices are 
attached and that the unit is not set to RS-422/485 2-
wire.  

 
 

5

C

C

o

o

n

n

n

n

e

e

c

c

t

t

 

 

P

P

o

o

w

w

e

e

r

r

 

 

S

S

u

u

p

p

p

p

l

l

y

y

 

 

 

 

A 10 to 48 VDC or 18 to 30 VAC external power supply 

is required. 

 

 Connect the power supply to the power terminal block 

located on the top of the radio modem.  

3

 

4

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

 

 

S

S

e

e

r

r

i

i

a

a

l

l

 

 

C

C

a

a

b

b

l

l

e

e

 

 

&

&

 

 

A

A

n

n

t

t

e

e

n

n

n

n

a

a

 

 

 

 

Connect a straight through RS-232 cable between the 

Radio Modem and your PC.  

 

Connect the antenna to the Radio Modem.  

Zlinx™ Manager  Start Screen 

 

 

Отзывы: