background image

1

OWNER'S MANUAL

________________

V93A DAC: 14.4k bps HOST
COMMUNICATION MODEM
MODULE FOR BAYTECH
M-SERIES DAC

BayTech Manual Publication #U140E116-02

Содержание U140E116-02

Страница 1: ...1 OWNER S MANUAL ________________ V93A DAC 14 4k bps HOST COMMUNICATION MODEM MODULE FOR BAYTECH M SERIES DAC BayTech Manual Publication U140E116 02 ...

Страница 2: ...ed and until repair has been made If this is not done the telephone company may temporarily disconnect service 3 The telephone company may make changes in its technical operations and procedures if such changes affect the compatibility or use of this device the telephone company is required to give adequate notice of the changes You will be advised of your right to file a complaint with the FCC 4 ...

Страница 3: ...operly In the event of equipment malfunction all repairs should be performed by our Company or an authorized agent It is the responsibility of users requiring service to report the need for service to our Company or to one of our authorized agents Service can be obtained at Bay Technical Associates Inc P O Box 387 200 N Second Street Bay St Louis MS 39520 U S A Phone 800 523 2702 or 228 467 8231 F...

Страница 4: ... EIA 232 CONNECTION 8 2 MODEM CONNECTION 11 5 OPERATION 11 1 LOGIN PASSWORD 11 2 PORT SELECTION MENU 12 3 MANUAL MODE 13 4 EXIT 14 5 UNIT RESET 15 6 LOGOUT 15 6 CONFIGURATION 16 1 STATUS 17 2 SERIAL PORT CONFIGURATION 17 3 PORT DEVICE NAME 19 4 PORT SELECT CODE 20 5 ATTENTION CHARACTER 20 6 DISCONNECT TIME GUARD 21 ...

Страница 5: ...5 7 LOGIN PASSWORD 21 8 LOCAL MODEM SETUP 22 9 EXIT 23 10 ECHO MODE 23 11 RING DETECT RESET 23 12 MODEM LED INDICATORS 23 7 V93A EPROM UPGRADE 24 8 V93A MECHANICAL LAYOUT 26 9 INDEX 27 ...

Страница 6: ...al to connect and issue specific configuration or data commands to the various I O modules or the M Series DAC unit main board Multiple V93A modules can be installed in a M Series chassis allowing I O modules to send data to specific V93A modules Please see the M Series DAC Owner s Manual for more information on the available types of I O modules IMPORTANT The first module slot of the M Series DAC...

Страница 7: ... Data CD Carrier Detect MR Modem Ready and CX Connection status LEDs TRANSMIT LEVEL 10 dBm dial up RECEIVER SENSITIVITY 45 dBm DIMENSIONS 6 h x 4 5 w FACTORY POWER UP DEFAULT CONFIGURATIONS Port Select Code BT Password BTA disabled USER PROGRAMMABLE CONFIGURATIONS Easy to configure using on screen menu Choices are saved in non volatile memory to become the new power up default configuration ...

Страница 8: ...screen first insert the diskette into your PC s disk drive and then enter the command TYPE README RDM from your disk drive prompt To print this file enter the command COPY README RDM LPT1 from your disk drive prompt 4 CABLES ADAPTERS The V93A modem has two modular connectors for device selection and configuration One connector is for connection to a dial up line The other connector is used to comm...

Страница 9: ...UE ORANGE BLACK RED GREEN YELLOW BROWN GRAY 1 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 TX RX RTS CTS DSR GND DCD DTR FEMALE DE 9 RJ 45 Figure 1 PC PS 2 Computer Terminal Adapter BayTech Part No 9FRJ45PC 3 Figure 2 shows the required adapter for a PC or terminal with a DB 25 connector Use a crossed RJ 45 cable to connect these adapters to the EIA 232 port ...

Страница 10: ... When modular connectors are used as shown in Figures 1 2 above with RJ 45 connectors crossed RJ 45 cables are required See the cable diagram that follows 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 PIN RJ 45 RJ 45 PIN 1 GRAY BROWN YELLOW GREEN RED BLACK ORANGE BLUE COLOR Figure 3 R J 4 5 C a b l e R J 4 5 C a b l e B a y T e c h P a r t N o R J 0 8 X 0 1 0 1 0 f e e t B a y T e c h P a r t N o R J 0 8 X 0 1 0 ...

Страница 11: ...tion software packages such as PROCOMM PLUS R by Data Storm Technologies also provide terminal emulation capabilities and allow for communications with the V93A c If configuring the V93A from the EIA 232 port configure the host terminal s serial parameters to match those of the V93A From the factory the V93A is set at 9600 baud 8 data bits 1 stop bit no parity and XON XOFF disabled 1 LOGIN PASSWOR...

Страница 12: ...ation commands are used to program the features of the various I O modules and the data commands are typically used to request stored data received from an I O module Data commands are also used to instruct certain I O modules to perform a specific task e g energize or de energize a relay The configuration menu is invoked by selecting configure C from the port selection menu The supported configur...

Страница 13: ...to the configuration mode for any installed modules or for the base unit See Section 6 CONFIGURATION for details to configure the unit 3 MANUAL MODE Manual Mode allows users to manually select a module and or port The Manual Mode selection for the V93A menu is used to make a module level connection which is used for sending commands to the module The Manual Mode is used to make a connection to a m...

Страница 14: ...er 2 Enter Port number CR for none 3 By entering 2 at the Enter Module number and entering 3 at the Enter Port number the user has selected module number 2 and port number 3 Verify the connection by insuring that the red LED of Port 3 Module 2 on the front panel of the M Series DAC base unit has been selected 4 EXIT By responding to the Enter Request message in the V93A Status Diagnostics Menu wit...

Страница 15: ...evice C 2 3 3 Device D 2 4 4 Device A 3 1 5 Device B 3 2 6 Device C 3 3 7 Device D 3 4 8 Configure C Manual Mode M Exit X Unit Reset R Logout T Enter Request R The M Series DAC unit has been reset Important The Unit Reset command will terminate communications with connected equipment to the M Series DAC You must re establish communications with the M Series DAC system after the unit has been reset...

Страница 16: ...it X Unit Reset R Logout T Enter Request To return to the menu after making a connection simply type 5 or more semicolons default NOTE Menu selection is case sensitive 6 CONFIGURATION To access configuration bring up the menu and select option C Select the module number associated with the V93A For example if the V93A is installed in module slot 4 select the number from the menu that is associated...

Страница 17: ...ord is BTA Strike any Key to Continue Port Device Baud Word Stop Parity Xon Xoff Name Rate Size Bits Xmit Recv 1 HostEIA 232 9600 8 1 None Off Off 2 Host MODEM 57 6k 8 1 None Off Off Strike any Key to Continue 2 SERIAL PORT CONFIGURATION By responding with 2 Serial Port Configuration you can change serial configuration for the EIA 232 port on the V93A The V93A will then respond with Enter Host Dev...

Страница 18: ...r 19200 8 For 38400 9 For 57 6K A For 76 8K B For 115 2K Enter Request Send B for 115 2K baud rate The V93A will respond with the reconfigured status of the port as follows Module 2 Serial Port Configuration Port Device Baud Word Stop Parity Xon Xoff Name Rate Size Bits Xmit Recv 1 Device A 115 2 8 1 None Off Off Exit Save 1 Set Stop Bits 4 Set Baud Rate 2 Set Parity 5 Set Word Size 3 Set Xon Xoff...

Страница 19: ...xt command If this happens cycle power on the M Series DAC and reconfigure the unit 3 PORT DEVICE NAME By responding with 3 Port Device Name you can change the Port Device Name The V93A module will respond with a menu similar to the following Module 1 Device Name Port Device Baud Word Stop Parity Xon Xoff Name Rate Size Bits Xmit Recv 1 Device D 9600 8 1 None Off Off Enter Port Device Name Max 16 ...

Страница 20: ...om 1 to 8 characters The V93A will respond with Port Select Code is BT Enter Port Select Code Max 8 characters or ENTER for no change Type the desired Port Select Code followed by ENTER For example if you type PORT followed by ENTER the V93A will respond with Port Select Code is PORT Enter Port Select Code Max 8 characters or ENTER for no change If no additional change is desired type ENTER The V9...

Страница 21: ...ine if you want a one second delay The V93A will respond with Disconnect Time Guard is Enabled Change It Y N N Type Y to toggle the existing state of Disconnect Time Guard or N for no change The V93A will store the selected state of the Disconnect Time Guard into non volatile memory and return to the main configuration menu 7 LOGIN PASSWORD By responding with 7 Login Setup you can change the Login...

Страница 22: ...it X Enter Request Type the number corresponding to your desired choice For example if you type 1 Rings to Answer the V93A will respond with Rings to Auto Answer 1 Change It Y N Type Y to change the Number Rings to Auto Answer setting The V93A will respond Enter Number of Rings to Auto Answer 1 to 4 The V93A will store the Number of Rings to Auto Answer in non volatile memory and return to the mai...

Страница 23: ...ved by the connected device back to that device Echo mode is terminated by placing an I O module into command mode BTm cr where m is the desired module number Echo Mode would be used only when the ASCII string method of port selection is used If the Menu Mode Attention character method of port selection is used the Echo Mode is not required 11 RING DETECT RESET The V93A has a Ring Detect Reset fea...

Страница 24: ...ROM UPGRADE You will receive one EPROM chip with label for each module to be upgraded The materials you will need to supply are Flat blade screwdriver IC DIP extractor or a pair of curved needle nose pliers 1 IMPORTANT Remove power from the unit by depressing the power switch on the front of the unit to OFF Also remove power cord from the AC outlet 2 Remove the appropriate module by loosening the ...

Страница 25: ...socket Be careful not to bend any of the pins Make sure none of the pins miss their sockets If the socket has more holes than chip pins the pins should line up starting at the edge of the board 5 Re install the V93A and apply power to the unit The upgrade is now complete Before you begin operations check the configuration status to make certain it matches your application See Section 5 for complet...

Страница 26: ...330A048A C15 C16 C19 C5 C6 C8 C9 J2 L1 L2 LED1 LED2 LED3 LED4 LED5 M1 R6 R7 U10 U11 U2 U8 U9 R9 F1 F2 K K È È F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F Error Switch argument not specified ...

Страница 27: ... Echo 18 L Local Modem Setup 20 Login Password 20 Login Setup 20 Logout 15 21 M Menu selection 15 Modular connectors 10 N Non volatile memory 17 19 O Off hook 21 P Port Device Name 18 Port Select Code 18 Port Selection 14 PROCOMM PLUS R 11 R README RDM 8 Reconfigured status 17 Reset 14 S Serial Port Configuration 16 Set Baud Rate 16 Status 16 T TERM EXE 8 11 Terminal emulation 10 Time out 21 U Uni...