When a warning occurs, a message is displayed on the OSD display and information display.
Error Codes
Code No.
Displayed message
Description
Operation
E-30
TURN POWER OFF
<P2 CARD>
Displayed when an error occurs in reading and writing card
data.
To continue operation, turn the power off and then back on.
Card removal
error
E-31
TURN POWER OFF
<SYSTEM MODE>
System mode error
To continue operation, turn the power off and then back on.
System error
E-35
SYSTEM ERROR
<CODEC>
CODEC microprocessor error
To continue operation, turn the power off and then back on.
System error
E-36
SYSTEM ERROR
<P2 SYSTEM>
P2CS microprocessor error (error notification)
To continue operation, turn the power off and then back on.
System error
E-37
SYSTEM ERROR
<P2CS>
P2CS microprocessor error (communication disconnected)
To continue operation, turn the power off and then back on.
System error
E-39
SYSTEM ERROR
<INITIALIZE>
Video initialization error
To continue operation, turn the power off and then back on.
Video
initialization
error
E-50
INPUT DC TOO LOW
Displayed when the input DV voltage is below the undercut
voltage.
Low voltage
E-55
OPT SYS ERROR
<SYSTEM>
<NOT RESPONSE>
<HALT>
Displayed when an error occurs with the system of the
AVCHD codec board AJ-YCX500G (option). To continue op-
eration, turn the power off and then back on.
System error
Display of warning information
Displayed message
Description
Deck operation
CANNOT REC
Displayed when data cannot be recorded on a P2 card.
[Cause]
• The card is write protected.
• No more free space on the card.
• Recording was attempted on a card that cannot be used.
• Card status changed during recording.
• Recording was attempted when the unit was BUSY.
STOP
CANNOT LOOP REC
Displayed when data cannot be recorded to a P2 card while the “RECORD-
ING” (
➝
page 86) menu item is “LOOP.”
[Cause]
• The card is write protected.
• No more free space on the card.
• Recording was attempted on a card that cannot be used.
• Card status changed during recording.
• Recording was attempted when the unit was BUSY.