INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN AN ALARM GOES OFF
OTHER
RECORD
MANAGEMENT
SECURITY ALARM SETTING
AND DISARMING
on
on
w
of
Gas Leak and Disconnection
79
In the Event of Gas Detector Fault
Alarm Stop
button
Ventilation indication
Flashing in red
Alarm Stop button
In the Event of Imperfect Combustion
How to stop the alarm message
Measures taken when alarm is sounding
How to stop the alarm sound
Measures taken when alarm is sounding
Note
(beep beep)
MENU button
MENU button
that
.
or
.
This function is available only if a gas detector
with the CO alarm function is installed.
When the gas/CO detector detects imperfect
combustion (carbon monoxide), the base unit
and the cordless handset of the door phone
report the abnormality.
(beep sound) The air is
contaminated. Please open a
window and ventilate the room.
The ventilation indicator will turn off after
approximately 3 minutes and the periphery of
the MENU button will flash in red.
If imperfect combustion is not detected
anymore, the alarm message automatically
stops and the periphery of the MENU button
and the alarm indicator lamp on the handset
of the door phone will turn off.
Note
●
The periphery of the MENU button and alarm
indicator lamp will keep flashing until the
gas/CO detector detects no more imperfect
combustion (carbon monoxide).
●
It is also possible to turn off the ventilation
indicator within 3 minutes. ( Page 75)
Press the Alarm Stop button. However, the alarm
sound of the gas/CO detector does not stop. (It
is also possible to stop the alarm sound from the
manager room. )
●
Open the windows and door to ventilate the
room.
●
Stop using the device causing the
imperfect combustion.
●
If the alarm message does not stop,
contact the store you purchased from or a
gas store.
When the detector is disconnected or removed,
the base unit and the cordless handset of the
door phone report the abnormality.
Gas
indicator
Lighting
in yellow
The gas detector fault indicator will turn off
after approximately 1 minute and the
periphery of the MENU button will flash in red.
If the gas detector is connected again or the removed
gas detector is reinstalled, the alarm message
automatically stops and the periphery of the MENU
button, gas indicator and the alarm indicator on the
handset of the door phone will turn off.
Note
●
The periphery of the MENU button and alarm
indicator lamp will keep flashing until the gas
detector or wiring is restored.
●
It is also possible to turn off the gas detector
fault display within 1 minute. ( Page 75)
Press the Alarm Stop button. (It is also possible to
stop the alarm sound from the manager room.)
If there is no abnormality on the gas detector
(the device is not removed and the breaker has
not tripped), contact the company that installed
the system or the administrating company.
Installer
Setting
It is also possible to disable the alarm feature.
Consult with the company that installed the
system or the administrating company.
Touching on the Confirm button will take you
back to the standby screen, and the periphery of
the MENU button will light up in red.
Pressing the MENU button will not take you back
to the gas detector fault indication screen. If you
want to keep displaying the gas detector fault
indication, touch on the top menu.
Gas detector
Abnormality
indication
Red light
Handset of the door phone
Alarm indicator lamp
Flashing in red
Alarm sounding
Handset of the door phone
Alarm indicator lamp
Flashing in red
Alarm sounding
7.Windea̲取説(英語)̲1M.indd 79
7.Windea̲取説(英語)̲1M.indd 79