site.signal.locationMargin
Optional Setting
NO
Default Value
10
Summary
Maximum difference in device signal strengths for locating.
Description
This is the maximum difference in
devices’
signal strength from a
wireless receiver and or wireless repeaters to be considered
equidistant.
site.signal.locationRcvrMarginReduce
Optional Setting
NO
Default Value
10
Summary
Amount to remove from a device’s wireless receiver signal
strength.
Description
Often devices have higher signal strength from a wireless receiver. By
reducing the wireless receiver signal strength, from a devices signal, it
will help balance device locating. Range value from 0 to 100.
site.system.ignore.lowbattery
Optional Setting
NO
Default Value
0
Summary
Are all Low Battery messages to be ignored?
Description
This will prevent Low Battery signals from being recorded on the
Maintenance Report. 1 = Yes, 0 = No
site.system.ignore.tamper
Optional Setting
NO
Default Value
0
Summary
Should Tamper Message be Ignored?
Description
This is used to ignore all system tamper messages. 1 = Yes, 0 = No
site.tampger.recordAagainMins
Optional Setting
NO
Default Value
1440
Summary
The number of minutes to record tampers signals again.
Description
This is number of minutes to wait between recording tamper signals
that show up in the maintenance report.
Содержание Palcare PAL-211401
Страница 1: ...Copyright 2018 PalatiumCare Inc Page 1 2018 Install Manual PAL 211401 FW 2 1 66 ...
Страница 10: ...Copyright 2018 PalatiumCare Inc Page 10 2018 Mounting hardware Layout WITH System Mounting Board Figure 1 0 ...
Страница 11: ...Copyright 2018 PalatiumCare Inc Page 11 2018 Mounting Hardware Layout WITHOUT system Mounting Board Figure 1 1 ...
Страница 12: ...Copyright 2018 PalatiumCare Inc Page 12 2018 PalatiumCare UL2560 System Mounting Layout Typical Figure 1 2 ...