External Components and Features
Sun Server X4-4 Overview
19
Component
Description
Note -
The back VGA port supports VESA Device Data Channel for monitor identification.
PCIe 3.0 I/O slots
Eleven PCIe 3.0 slots that accommodate low-profile PCIe cards.
■ All slots support x8 PCIe connections
■ Slots 1 through 7, 9, and 10: x8 connector
■ Slots 8 and 11: x8 or x16 connector
Note -
PCIe slots 7 through 11 are only functional in four CPU systems.
PCI Express I/O
cards
For a list of supported I/O cards, refer to the
Product Notes
.
Ethernet ports
Four 10 GbE RJ-45 Ethernet ports (back panel)
Service processor
Emulex Pilot 3 base management controller (BMC):
■ Supports the industry-standard IPMI feature set
■ Supports remote KVMS, DVD, and floppy over IP, and ISO image over IP
■ Includes serial port
■ Supports Ethernet access to SP through a dedicated 10/100/1000 RJ-45 Gigabit Ethernet
(GbE) management port and optionally through one of the host GbE ports (sideband
management)
Power supplies
Two hot-swappable power supplies, each with 1030/2060 watts (low line/high line) capacity,
auto-ranging, light load efficiency mode and redundant over-subscription
Cooling fans
■ Six hot-swappable, redundant fans at chassis front (top-loading)
■ Two redundant fans, one in each power supply
Management
software
The following options are available:
■ Oracle Integrated Lights Out Manager (ILOM) on the Service Processor.
■ Oracle System Assistant (OSA) on an optional internal USB flash drive.
■ Oracle Hardware Management Pack.
■ Oracle Enterprise Management Ops Center, which can be downloaded from the Oracle
site.
External Components and Features
The following sections call out the features of the server front and back panels.
■
“Server Front Panel Features” on page 19
■
“Server Back Panel Features” on page 20
Server Front Panel Features
The following illustration shows the server front panel and describes its features.
Содержание Sun Server X4-4
Страница 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Страница 2: ......
Страница 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Страница 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Страница 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Страница 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Страница 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Страница 123: ...Remove a Power Supply Servicing CRU Components 123 3 Disconnect the power cord from the failed power supply ...
Страница 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Страница 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Страница 292: ...292 Sun Server X4 4 Service Manual October 2015 ...