Install a Memory Riser Card
Servicing CRU Components
139
1.
Ensure that all populated and unpopulated DIMM slot ejector levers are in the
closed and locked position.
Caution -
Component damage. Open DIMM ejector levers can break off during the installation
of the memory riser (MR) card. All populated and unpopulated DIMM slot ejector levers on the
MR card must be in the fully-closed and locke position before installing the card in the server.
2.
Ensure that the MR card ejector levers are in the closed position.
The ejector levers are only used to remove a MR card and are
not
used to install a card.
3.
Orient the MR card over the slot on the motherboard.
The DIMMs on the card must face the left (when positioned at the front of the server).