![Oracle Sun Server X4-4 Скачать руководство пользователя страница 210](http://html1.mh-extra.com/html/oracle/sun-server-x4-4/sun-server-x4-4_service-manual_1646170210.webp)
Replace the Disk Drive Backplane (FRU)
210
Sun Server X4-4 Service Manual • October 2015
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 66
.
1.
Prepare the server for service. See
.
2.
Remove and label all disk drives and fillers. See
To ensure that the drives are returned to their slots, label the drives with their slot position.
3.
“Remove the DVD Drive or DVD Drive Filler
.
4.
Disconnect the power cable, ribbon data cable, and any SAS/SATA cables from
the disk drive backplane.
You do not need to remove the cables from the HBA board.
5.
To move the air divider:
You need to move the air divider, so you can access to the disk drive backplane board. The
divider is mounted to the power supply side wall using two tabs, which are inserted into slots in
the side wall.
a.
Lift the air divider so the tabs clear the slots in the power supply housing
side wall.
b.
Move the air divider away from the side wall, lift it up, and bend the cables,
so you can rotate the divider away from the backplane and set it in the PCIe
slot area.
The disk drive backplane sets on metal flanges and is secured by a spring-loaded lever.
6.
Disconnect the ribbon data cable and the power cable at the bottom of the disk
backplane board.
See the illustration shown in step 7.
7.
To release the spring-loaded lever, lift it upward.
Содержание Sun Server X4-4
Страница 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Страница 2: ......
Страница 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Страница 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Страница 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Страница 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Страница 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Страница 123: ...Remove a Power Supply Servicing CRU Components 123 3 Disconnect the power cord from the failed power supply ...
Страница 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Страница 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Страница 292: ...292 Sun Server X4 4 Service Manual October 2015 ...