Remove a Memory Riser Card
Servicing CRU Components
131
You must replicate this same DIMM population configuration on the replacement card.
The slots are color coded (for more information, see
).
Note -
Ensure that you replicate the same DIMM configuration on the replacement card.
5.
Transfer the DIMMs from the slots on the faulty MR card to the same slots on the
replacement card:
Tip -
Transfer the DIMMs from the faulty card to the replacement card one at a time.
a.
Remove a DIMM from the faulty MR card. See
.
b.
Install the DIMM on the replacement card. See
.
c.
Repeat the above steps until all DIMMs are transferred from the faulty card
to the replacement card.
6.
“Install a Memory Riser Card” on page 138
7.
Prepare the server for operation. See
.
Remove a Memory Riser Card
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Use this procedure to remove a memory riser (MR) card to:
■
Содержание Sun Server X4-4
Страница 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Страница 2: ......
Страница 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Страница 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Страница 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Страница 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Страница 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Страница 123: ...Remove a Power Supply Servicing CRU Components 123 3 Disconnect the power cord from the failed power supply ...
Страница 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Страница 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Страница 292: ...292 Sun Server X4 4 Service Manual October 2015 ...