Install a Memory Riser Card
138
Sun Server X4-4 Service Manual • October 2015
4.
Ensure that the levers have risen completely and have locked the DIMM in the
slot.
5.
Repeat the above steps until all replacement DIMMs are installed.
Caution -
Component damage. Open DIMM ejector levers can break off during the installation
of the memory riser (MR) card. All populated and unpopulated DIMM slot ejector levers on the
MR card must be in the fully-closed position before installing the card in the server. Ensure that
all levers are closed and locked.
Next Steps
■
“Install a Memory Riser Card” on page 138
Install a Memory Riser Card
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Use this procedure to install a memory riser (MR) card into its slot.
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 66
.
■
For DIMM designation information, see
“Component Designations” on page 69
.
■
For reference information, see
“Memory Riser Card and DIMM Reference” on page 141
.
Содержание Sun Server X4-4
Страница 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Страница 2: ......
Страница 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Страница 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Страница 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Страница 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Страница 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Страница 123: ...Remove a Power Supply Servicing CRU Components 123 3 Disconnect the power cord from the failed power supply ...
Страница 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Страница 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Страница 292: ...292 Sun Server X4 4 Service Manual October 2015 ...