Replace the Disk Drive Backplane (FRU)
214
Sun Server X4-4 Service Manual • October 2015
14.
Reconnect the ribbon data cable and power cable to the bottom of the disk
backplane board.
15.
To install the air divider:
Note -
The air divider contains the Fault Remind button mechanism. To ensure that the
mechanism can engage the motherboard-mounted switch, the divider
must
be installed
correctly.
a.
Ensure the SAS/SATA cables are routed through the slot in air divider.
The back side of the divider has enough room to house the cables if they are flat and side-
by-side. Do not allow the cables to interfere with the Fault Remind button mechanism.
b.
Align the two tabs on the divider with the three slots in the power supply
side wall.
c.
Push the tabs into the slots and push the divider downward to secure it
against the wall.
Содержание Sun Server X4-4
Страница 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Страница 2: ......
Страница 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Страница 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Страница 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Страница 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Страница 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Страница 123: ...Remove a Power Supply Servicing CRU Components 123 3 Disconnect the power cord from the failed power supply ...
Страница 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Страница 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Страница 292: ...292 Sun Server X4 4 Service Manual October 2015 ...