v1.12
Cloudberry Management – PTP Management User Manual
- 47 -
parentDS.grandmasterClock
Quality member data set.
parentdsGrandmasterClockQualityClockAccuracy
Hex
Read-only
This parameter is read from
the
parentDS.grandmasterClock
Quality member data set.
parentdsGrandmasterClockQuality-
OffsetScaledLogVariance
Integer
(16bit)
Read-only
This parameter is read from
the
parentDS.grandmasterClock
Quality member data set.
parentdsGrandmasterPriority2
Integer
(8bit)
Read-only
This parameter is read from
the
parentDS.grandmasterPriority
2 member data set.
parentdsGrandmasterIdentity
Hex
string
Read-only
This parameter is read from
the
parentDS.grandmasterIdentit
y member data set.
1.4.8 PTP time property data set
Parameter
Type
Read/Write Description
timepropdsCurrentUTCOffset
Integer
(16bit)
Read-only
This parameter is read from the
timePropertiesDS.currentUtcOffset
member data set.
timepropdsFlags
Hex
Read-only
his parameter is read from the
timePropertiesDS:
- leap61 (0x01)
- leap59 (0x02),
- currentUtcOffsetValid (0x04)
- ptpTimescale (0x08),
- timeTraceable (0x10) and
- frequencyTraceable (0x20)
member data set.
timepropdsTimeSource
Hex
Read-only
This parameter is read from the
timePropertiesDS.timeSource
member data set.
1.4.9 PTP port data set
Parameter
Type
Read/Write Description
portdsPortIdentityClockId ,
Hex
string
Read-only
This parameter is read from
the
portDS.portIdentity
member data set.
portdsPortIdentityPortNumber
Integer
(16bit)
Read-only
This parameter is read from
the
portDS.portIdentity
member data set.
portdsPortState
Integer
Read-only
This parameter is read from
the portDS.portStats member
data set.