v1.12
Cloudberry Management – PTP Management User Manual
- 44 -
user defined physical location.
Table 1, clockDesc
1.4.2 Save to non volatile storage
Parameter
Type
Read/Write Description
saveInNoneVolatileStorage
Boolean Write
PTP action command for saving
PTP parameters to non volatile
memory.
1.4.3 Create initialization event
Parameter
Type
Read/Write Description
init
Boolean Write
INITIALIZATION event to the PTP
clock state machine.
1.4.4 Clock accuracy
Parameter
Type
Read/Write Description
clockType
Hex
Read/write
This parameter specifies the accuracy
of the clock. See table 6 in IEEE1588
Std 2008.
The
defaultDS.clockQuality.clockAccuracy
will be updated if this parameter is
set..
1.4.5 PTP default data set
Parameter
Type
Read/Write Description
defaultdsFlags
Text
Read/write
0x01 = Two step flag (*),
0x02 = Slave Only flag.
(*) The IEEE1588 Std
2008 (v2) specifies that
this flag shall be read-
only, but the user is
allowed to modify this flag
on
this
PTP
clock
implementation.
The flag will be forced to
2-step
operation
if
IEEE1588 Std 2002 (v1)
is selected,
see
portdsVersionNumber in
the port data set.
defaultdsNumberPorts
Integer
(16 bit)
Read-only
This parameter specifies
the number of ports on
the clock.