Cloudberry Management – PTP Management User Manual 

 

 

- 1 -

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

Cloudberry Management – PTP User Manual 

 

 

Содержание CM-1600

Страница 1: ...v1 12 Cloudberry Management PTP Management User Manual 1 Cloudberry Management PTP User Manual...

Страница 2: ...1 3 2 Configuration popup 38 1 3 3 Upgrade of multiple devices 41 1 4 PTP PARAMETERS AND DATA SETS 43 1 4 1 ClockDesc data set 43 1 4 2 Save to non volatile storage 44 1 4 3 Create initialization eve...

Страница 3: ...1600 from OnTime Networks The CM 1600 platform contains two CPUs The switch CPU is used for switch management and the PTP CPU is used for the PTP IEEE 2002 and IEEE 2008 protocol Separate IP addresse...

Страница 4: ...ool is bundled together with the PTPBrowser tool in the same installation Via IPSet you can Set IP address mask and gateway Upload PTP settings file Configure PTP settings Upgrade the PTP CPU Read sof...

Страница 5: ...ou select an interface the three image buttons on the bottom are disabled You may start different sessions on different interfaces and IPSet will search for devices on the specified interface Note tha...

Страница 6: ...displays detailed information about the unit All configuration options are available Start IPSet with simplified configuration IPSet searches for devices on the selected interface and shows a subset...

Страница 7: ...le column Description PTP MAC Address MAC address of the PTP CPU PTP IP Address IP Address of the PTP CPU Mask Mask of the PTP CPU The mask will be set equal on the PTP CPU and the Switch CPU when set...

Страница 8: ...address of the PTP CPU PTP IP Address IP Address of the PTP CPU Switch MAC Address MAC address of the Switch CPU Switch IP Address IP Address of the Switch CPU Mask Mask of the Switch CPU The mask wi...

Страница 9: ...BRATED PTP Delay Mechanism PTP Delay mechanism Valid states are End to End or Peer to Peer PTP Version PTP version 2 equals IEEE1588 2008 PTP Version 1 equals IEEE1588 2002 Two Step False One Step Tim...

Страница 10: ...t PTP Management User Manual 10 1 2 4 Time The Time pane shows the time of the device in the PTP time scale Table column Description MAC Address MAC address of the PTP CPU PTP IP Address IP Address of...

Страница 11: ...TP CPU PTP Image Selected Image which will be run at next boot The PTP CPU has dual images PTP Image Booted Current running image PTP Uboot revision Bootloader version PTP Software revision PTP softwa...

Страница 12: ...settings IP address via IPSet DHCP PTP CPU DHCP enabled disabled PTP State PTP state of the device Valid states MASTER SLAVE INITIALIZING PASSIVE UNCALIBRATED PTP Delay Mechanism PTP Delay mechanism...

Страница 13: ...and above The column called temperature shows the temperature at one of the edges of the switch board which is closest to the air temperature within the box The FPGA temperature column shows the tempe...

Страница 14: ...described below 1 2 8 1 Set IP address Here you may change the IP address mask gateway for both CPUs and enable disable the DHCP client for the PTP CPU Note that the mask and gateway of the switch CPU...

Страница 15: ...lds shall be white However the settings are not applied to the running configuration In order to run with the new settings the PTP CPU must be rebooted The Reboot PTP CPU button will force a reboot of...

Страница 16: ...elay req interval The frequency of Path Delay request messages Announce interval The frequency of Announce messages Sync interval The frequency of Sync messages Delay request interval In SLAVE state t...

Страница 17: ...nsparent clock and an Ordinary clock Telecom profile Telecom profile Settings UDP Ipv4 Unicast E2E 128 Sync s 128 Delay_req s One step This option may be grayed out depending of the firmware version o...

Страница 18: ...interface Serial settings must also be configured Note that not any GPS may be used since they often have proprietary configuration protocols Contact OnTime Networks if a different GPS than the stand...

Страница 19: ...ature enables and disables PTP functionality completely on the selected port In TC translator mode it is possible to set the PTP version as well as the encapsulation on each port The PTP Translation s...

Страница 20: ...v1 IEEE1588 2002 PTP v2 IEEE1588 2008 Layer 2 Transport over IEEE802 3 Ethernet UDP IPv4 Transport over UDP IPv4 PTP Port enable disable Enable or disable PTP functionality on a port A checked box ind...

Страница 21: ...te GPS is chosen you may set the protocol to emulate here Baud rate The speed of the serial port Delay after PPS ms When Emulate GPS is selected you may select the delay to wait after the PPS signal b...

Страница 22: ...Selecting I O will redirect focus to the Serial tab RS422 Serial port 2 Console Currently disabled I O Output signals such as PPS and IRIGB 002 may be chosen as output signals for this port Note that...

Страница 23: ...LAN settings valid when the transportation method is IEEE802 3 Ethernet Section Description VLAN setting When using IEEE803 2 Ethernet Layer2 as transportation method it is possible to insert a VLAN t...

Страница 24: ...ually from IPSet via this menu Device time PTP Time TAI This is the devices true time clock If no time is visible the device does not answer the GET TIME dataset Device time From TAI This is the devic...

Страница 25: ...lly uses a time zone and leap seconds Clock and Date selection Select the time which shall be set manually to the device The format is HH MM SS and the date is selectable by a drop down menu The field...

Страница 26: ...lways possible to find the device via IPSet regardless of any filters set Filter modes There are two main filter modes Allow and Block filters The Allow filter will only allow the UDP packets which ma...

Страница 27: ...e other selected source port filters UDP DST If the Filter on selection is UDP SRC DST one UDP destination port may be selected For setting the filter you must write to the field directly and pushing...

Страница 28: ...s with every other setting the filter is uploaded to the device after clicking the Set button Until then the change is only local in IPSet If you have configured wrongly and want to start from the set...

Страница 29: ...table on the available outputs Note that the devices have different number of available outputs and the GUI will reflect the version which is under configuration Connector pin out is also included in...

Страница 30: ...nable Enable or disable the output Enable RS422 Enable the RS422 port for the selected signal Note that both the TTL signal and the RS422 serial port output may be active at the same time Enabling the...

Страница 31: ...ble Special buttons such as escape Esc control Ctrl and similar will not work 1 2 8 4 Upload PTP settings file As an alternative to modifying the settings directly you may upload a configuration file...

Страница 32: ...tton will be enabled Upgrade is then started by pressing the upgrade button Status and progress will displayed during upgrade Note that IPSet will start a TFTP server on your computer Please make sure...

Страница 33: ...1 2 8 6 Reboot PTP CPU This choice reboots the PTP CPU Note that a reboot of the PTP CPU will not affect the switch functionality since a reboot of the device is not performed 1 2 8 7 Reboot Device Th...

Страница 34: ...ult settings and reboot the whole device The default network settings are PTP CPU IP 192 168 10 2 Mask 255 255 255 0 Gw 192 168 10 1 Switch CPU IP 192 168 10 1 Mask 255 255 255 0 Gw 192 168 10 1 Note...

Страница 35: ...e the switch management documentation for further information 1 2 9 Management Upgrade of multiple devices The Select all button or clicking on the check buttons on the left side will enable simple ma...

Страница 36: ...grade will be visible during the upgrade procedure When an upgrade is finished the Status will display Finished For the new image to take effect the PTP CPU must be rebooted Reboot of multiple devices...

Страница 37: ...f the device For instance CM 1600 Serial number The serial number of the device this number is also written on the device mechanics Mechanics Details regarding the mechanics of the device Hostname An...

Страница 38: ...3 2 1 Set IP address Here you may change the IP address mask gateway for both CPUs and enable disable the DHCP client for the PTP CPU Note that the mask and gateway of the switch CPU is automatically...

Страница 39: ...itch will always be a transparent clock but can also be SLAVE or MASTER in a system Note that even though you configure MASTER it may go into PASSIVE mode or SLAVE mode depending whether there is a MA...

Страница 40: ...rable per port 1 3 2 2 1 Advanced filtering section When advanced filtering is selected on a port a new tab is opened for advanced filtering This tab is the same as the UDP filtering tab described ear...

Страница 41: ...devices in the same network you may encounter IP address conflicts since the IP address of several devices may be equal 1 3 3 Upgrade of multiple devices Clicking on the check buttons on the left sid...

Страница 42: ...grade will be visible during the upgrade procedure When an upgrade is finished the Status will display Finished For the new image to take effect the PTP CPU must be rebooted Reboot of multiple devices...

Страница 43: ...er protocol e g Ethernet physicalAddressLength Integer Read only This parameter specifies the length of the physical address physicalAddress Hex string Read only This parameter specifies the physical...

Страница 44: ...ype Hex Read write This parameter specifies the accuracy of the clock See table 6 in IEEE1588 Std 2008 The defaultDS clockQuality clockAccuracy will be updated if this parameter is set 1 4 5 PTP defau...

Страница 45: ...member data set See tabel 5 in IEEE 1588 Std 2008 See tabel 5 in IEEE 1588 Std 2008 defaultdsPriority2 Integer 8 bit Read write This parameter is read from the defaultDS priority2 member data set Rang...

Страница 46: ...ntdsParentStats Boolea n Read only This parameter is read from the parentDS parentStats member data set The value of parentDS parentStats shall indicate whether the values of parent observedParentOffs...

Страница 47: ...ta set Parameter Type Read Write Description timepropdsCurrentUTCOffset Integer 16bit Read only This parameter is read from the timePropertiesDS currentUtcOffset member data set timepropdsFlags Hex Re...

Страница 48: ...rite This parameter is read from the portDS announceReceiptTime out member data set portdsLogSyncInterval Integer Read write This parameter is read from the portDS logSyncInterval member data set port...

Страница 49: ...rentClockPortDS portIdentity numberPorts member data set for each of the ports on the TC switch tcportdsFaultyFlag Hex Read only This parameter is read from the transparentClockPortDS fa ultyFlag memb...

Страница 50: ...n the Interface IP address choicebox After the interface is chosen you may start PTPBrowser After startup PTPBrowser will query for a number of datasets via multicast PTP management messages and liste...

Страница 51: ...devices in the Ordinary Clocks pane according to their state and accuracy GREEN Slave device within the Min Max offset in ns RED Slave device outside the Min Max offset in ns BLUE Maste device GRAY De...

Страница 52: ...vided for the different PTP messages 1 5 4 Settings pane 1 5 4 1 Scan configure The scan configure button opens a new instance of the IPSet tool 1 5 4 2 Animate offset PTP This button opens a dialog w...

Страница 53: ...1 12 Cloudberry Management PTP Management User Manual 53 1 5 4 3 Configure PTP You may set the following parameters via PTP management Delay Mechanism Path Delay request interval Priority 1 Priority 2...

Страница 54: ...cted in the leftmost menu of the settings frame Note that these parameters are not stored to flash and will only be relevant for testing In order to store the parameters permanently use the Configure...

Страница 55: ...P time fields are decoded from the currentTime Field An Alias can be specified in the alias csv file For now this must be changed manually in the file Examples are included The Alias for the matching...

Страница 56: ...manage network performance find and solve network problems and plan for network growth Network management systems can via SNMP either poll network nodes for information or receive messages called tra...