Section 3
Setting Output Processing of Sensing Information
3-25
ZS-L
User’s Manual
■
Triggers
Set the input method for the timing of the start and end of the measurement period.
FUN Mode-[OUTPUT]-[HOLD]-[TRIGGER]
SAMPLE
Holds the measured value at the start of the sampling period. The output
changes at the start of the sampling period and is held until the start of the
next sampling period.
Setting
Description
EXT
Enters the trigger for the start of sampling by using the timing input. The period
that the timing signal is ON is the sampling period.
(default value)
When a delay time is set, the input OFF timing and the end of the
sampling period will not be synchronous. Sampling will end after the
specified sampling period has elapsed.
SELF-UP
The sampling period is the period that the measured value is greater than the
specified self-trigger level. Hold measurement is possible without a sync input.
When SELF-UP is selected, the following items are subsequently displayed:
• TRG LEVEL
Sets the desired self-trigger level.
Range: -999.99 to 999.999
• TRG HYS
Sets the hysteresis width for the self-trigger.
Range: 0 to 999.999
When a delay time is set, the timing when the measured value
becomes smaller than the self-trigger level and the end of the sam-
pling period will not be synchronous.Sampling will end after the speci-
fied sampling period has elapsed.
Setting
Description
Sampling period
Current
measured value
Output
ON
OFF
Sampling period
Timing input
Sampling period
Sampling period
Self-trigger
level
Measured
value
Action point
Hysteresis width
(for self-trigger)
Return point
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......