Se
c
tion 3
SE
T
U
P
Section 3
Setting Output Processing of Sensing Information
3-21
ZS-L
User’s Manual
FUN Mode-[OUTPUT]-[SCALING]-[ON]-[AUTO]
1.
Set the sensing object in place, and enter the
desired setting to be used as the offset.
The current measured value is displayed on the main
display, and the offset value is displayed on the sub-
display.
2.
Press the SET Key to apply the setting.
3.
Set the decimal point to determine the effective
digits.
The decimal point set here becomes the new decimal
point of the scaling setting. The position of the decimal
point on the display follows the “DOT” setting of the dis-
play setup in the RUN mode.
4.
Press the SET key to apply the setting.
5.
Press the SET key without entering any value for
the second point.
6.
Select [FORWARD] or [INVERS].
FORWARD: The larger the distance between the Sensor Head and the sensing object, the larger
the measured value displayed on the Sensor Controller.
INVERS: The larger the distance between the Sensor Head and the sensing object, the smaller the
measured value displayed on the Sensor Controller.
INPUT POINT 1
VAL SET:OK
DIG
INPUT DOT POINT
VAL SET:OK
DIG
INPUT POINT 2
VAL SET:OK
DIG
CHANGE DIRECTION
1 FORWARD 2 INVERS
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......