Setting the Sensing Conditions
Setting the Measurement Object
Set the type of workpiece to be measured.
FUN Mode-[SENSING]-[OBJECT]
Setting
Description
NORMAL
Usually, select this setting.(default value)
PCB
Select this setting for workpieces such as PCBs through which light pene-
trates.
MIRROR
Select this setting for workpieces having a mirror surface.
GLASS
Select this setting for workpieces having a glass surface.
THICK
NORMAL
Select this to measure the thickness of raw glass.
Measures the thickness between (1) and (2).
FILM
Select this to measure the thickness of glass with a film coating.
Measures the thickness of the glass having different reflection factors on the
front side (1) and the backside (2) such as backside deposited glass.
STOP
Select this to measure the thickness of still workpieces.
MOVE
Select this to measure the thickness of moving workpieces.
GAP
NORMAL
Select this to measure the gap between raw glass.
Measures the gap between (2) and(3).
Top side (1)
Rear side (2)
Thickness measurement
Raw glass
Glass with a film coating
With vapor-deposited film,
etc. on rear side
Top side (1)
Rear side (2)
Thickness measurement
Gap measurement
Raw glass
Raw glass
Top side (1)
Rear side (2)
Top side of raw glass
underneath upper raw glass
(3)
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......