3-16
Se
c
tion 3
SE
T
U
P
ZS-L
User’s Manual
Section 3
Setting the Sensing Conditions
Setting Prevention of Mutual Interference
Mutual interference between two Sensor Heads can be prevented by shifting the laser
beam emission timing. Use this function when Sensor Heads must be set up inside an
area where mutual interference is likely to occur or when a transparent workpiece will be
measured sandwiched between two Sensor Heads.
FUN Mode-[SENSING]-[SYNC]
The measurement cycle is changed when the mutual interference prevention mode is enabled.
• 8 times in the STAND, HI-RESO and HI-SENS modes
• About 15 times in the HI-SPEED mode
• The measurement cycle is also influenced by other settings.
• Check the current measurement cycle by FUN Mode-[SYSTEM]-[INFO]-[CYCLE].
• The same sensing mode must be set to each controller when the mutual interference prevention
mode is used. When [HI-SPEED] or [CUSTOM] is selected as the measurement mode, the same con-
ditions must be set. Setting different conditions will result in a different measurement cycle on each
controller and mutual interference can no longer be prevented.
• The mutual interference prevention function does not operate when THICK or GAP is set.
Setting
Description
OFF
The mutual interference prevention function is not used. (default value)
ON
Timing A
Sets the light emission timing to timing A.
Timing B
Sets the light emission timing to timing B.
H
LD ON ZERO ENABLE
P
L
H
LD ON ZERO ENABLE
P
L
H
LD ON ZERO ENABLE
P
L
Glass
Sensor Head 1
Timing A
Sensor Head 2
Timing B
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......