6-12
S
e
ct
ion 6
AP
PE
NDIX
ZS-L
User’s Manual
Section 6
APPENDIX
F.S.: Full scale of measurement
(*1)
Defined as 1/e
2
(13.5 %) of the center optical intensity in the measurement center distance (effective value). The beam
diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam.
(*2)
This is the error on the measured value with respect to an ideal straight line. The standard workpiece is white
aluminum ceramics. (In the regular reflection mode on ZS-LD50, the standard workpiece is glass.)Linearity may
change according to the workpiece.
(*3)
This is the “Peak-to-peak” displacement conversion value of the displacement output in the measuring center
distance when the number of samples to average is set to 128, and the measuring mode is set to the high-resolution
mode. The standard workpiece is white aluminum ceramics. (In the regular reflection mode on ZS-LD50, the standard
workpiece is glass.)
(*4)
This is the value obtained in the measuring center distance when the sensor and workpiece are fixed by an aluminum
jig (typical example).
(*5)
This value is obtained when the measuring mode is set to the high speed mode.
(*6)
Europe : Class2 of EN60825-1(IEC60825-1)
Item
ZS-LD130
ZS-LD200
ZS-LD350
Optical system
Diffuse
reflection
Regular
reflection
Diffuse
reflection
Regular
reflection
Diffuse
reflection
Measuring center
distance
130 mm
200 mm
350 mm
Measuring range
±15 mm
±12 mm
±50 mm
±48 mm
±135 mm
Light source
Visible semiconductor laser (wavelength 650 nm, 1 mW max., Class 2 (*6))
Beam diameter
(*1)
600 x 70
µ
m
100 x 900
µ
m
240 dia.
µ
m
Linearity
(*2)
±0.1%F.S.
±0.25%F.S.
±0.1%F.S.
±0.1%F.S.
Resolution
(*3)
3
µ
m
5
µ
m
20
µ
m
Temperature charac-
teristic
(*4)
0.02%F.S./°C
0.04%F.S./°C
Sampling cycle
(*5)
110
µ
s
LED
indica-
tor
NEAR indi-
cator
Lit near measuring center distance, and nearer than measuring center distance inside
the measuring range
Flashes when the measurement target is outside of the measuring range or when the
received light amount is insufficient
FAR indica-
tor
Lit near measuring center distance, and further than measuring center distance inside
the measuring range
Flashes when the measurement target is outside of the measuring range or when the
received light amount is insufficient
Operating ambient
illumination
Illumination on received light surface
2000lx or less (incandescent light)
Illumination on received light surface 3000lx or
less (incandescent light)
Ambient temperature Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Degree of protection Cable length 0.5 m: IP66, cable length 2 m: IP67
Vibration resistance
(destructive)
10 to 150 Hz (0.7 mm double amplitude) 80 min each in X, Y an Z directions
Materials
Case: aluminum die-cast, front cover: glass
Cable length
0.5 m, 2 m
Weight
Approx. 350 g
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......