S
ect
io
n
2
IN
STALLATION &
CONNECTI
O
N
Section 2
About the I/O cable
2-7
ZS-L
User’s Manual
About the I/O cable
■
Wiring the I/O cable
The following shows the leads that comprise the I/O cable.
(1) Power supply
This connects the 24 VDC (±10) power supply. When using a Sensor Controller with a
PNP output, the power supply terminal is also the common I/O terminal for all I/O
except for the linear output.Supply power from a DC power supply unit that has a coun-
termeasure (safety ultra-low voltage circuit) built-in for preventing high voltages from
occurring.
Recommended power supply unit p.1-9
Wire the power supply separately from other devices. Wiring them together or placing
them in the same duct may cause induction, resulting in malfunction or damage.
(2) GND
The GND terminal is the 0V power supply terminal. When using a Sensor Controller
with an NPN output, the GND terminal is also the common I/O terminal for all I/O
except for the linear output.
(3) OUT0 (HIGH output)
This outputs judgment results (HIGH).
(4) OUT1 (PASS output)
This outputs judgment results (PASS).
(5) OUT2 (LOW output)
This outputs judgment results (LOW).
(6) OUT3 (ENABLE output)
This turns ON when the sensor is ready for measurement. This output is interlocked
with the ENABLE indicator.
(1) Power supply
(3) OUT0
(4) OUT1
(5) OUT2
(6) OUT3
(7) OUT4
(8) Linear output
(9) Linear GND
(10) IN0
(11) IN1
(12) IN2
(13) IN3
(14) Unused
(2) GND
Brown
Blue
Red
Green
Black
Pink
Gray
Co-axial (black)
Shielded
Yellow
Light blue
Purple
White
Orange
Содержание ZS-L -
Страница 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Страница 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Страница 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Страница 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Страница 158: ......