2
Measurement
96
Shape
FZ3 Processing Items List Manual
2.
Use the drawing tools to specify the model registration range.
3.
This sets the model parameter.
Setting item
Set value
[factory default]
Description
Angle range
Upper limit
-180 to 180
[0]
When the measurement object is rotating, set
how large the angle range is for creating rotated
models.The skipping angle is set automatically.
Lower limit
-180 to 180
[0]
Reverse
●
Checked
●
[Unchecked]
Specify whether to allow the reverse of light and
dark for the model.
Size change
●
Checked
●
[Unchecked]
This is set when the size of measurement
objects changes. When checked, tap [Detail
setting] and specify a value for each item.
4.
When the "Size change" option is checked, tap [Detail setting].
The "Model parameter: Size change" area is displayed.
Setting item
Set value
[factory default]
Description
Move axis
●
[XY]
●
X
●
Y
Specify the model variable direction.
Move range
Upper limit
[100] to 110
Specify the range in which to change the
model size.
Lower limit
90 to [100]
5.
Tap [Return].
The "Model parameter" area is displayed.
Important
●
Set the region such that the number of pixels in the model region is 995328 pixels or less.
●
Sometimes detection exceeds the set angle range.
●
When the angle range is set and the image registered as a model is measured, some error occurs in the
rotation angle.
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...