2
Measurement
116
Edge Position
FZ3 Processing Items List Manual
Note
●
The edge is scanned from the start point of the area toward the end point.
When setting up the measurement region, pay attention to the detection direction of the edge.
●
Measurement cannot be performed if there is no edge within the measurement region.When determining the
size and position of the measurement region, take into account the movement range of the measurement object.
1.
In the Item Tab area, tap [Region setting].
2.
Use the Drawing tools to specify the measurement region.
3.
In the figure setting area, tap [OK].
The measurement region is registered and displayed in the Image Display area.
Note
●
Use the zoom function if the measurement region is too small to identify the direction of the arrow.
Reference:
"Using the Zoom Function" in the "User's Manual" (p.317)
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...