4
Support
measurement
FZ3 Processing Items List Manual
Trend Monitor
371
Setting item
Set value
[Factory default]
Description
Upper
-999999999.9999 to
999999999.9999
Specify the range where the measurement result is
judged to be OK.
Lower
-999999999.9999 to
999999999.9999
Referred max
/ min of
indication
range
●
[Checked]
●
Unchecked
When checked, the judgement range that can be set
with the upper and lower values becomes the same as
the max. and min. values set in [Display range].
Note
●
If the window is entered after measurement is performed a few times and [Default] is tapped on, optimal
judgement conditions including maximum and minimum measurement values are automatically set.
3.
In the "Warning" area, specify values for "Upper" and "Lower".
The setup method is the same as the setup method for the "Judgement" area.
Setting item
Set value
[Factory default]
Description
Upper
-999999999.9999 to
[999999999.9999]
Specify the warning range for encouraging caution
before frequent occurrence of NGs.
Lower
[-999999999.9999] to
999999999.9999
Referred
max / min of
indication
range
●
[Checked]
●
Unchecked
When checked, the judgement range that can be set with
the upper and lower values becomes the same as the
max. and min. values set in [Display range].
Measurement History Display (Trend Monitor)
Displays measurement history.
1.
Tap [History display] in the Item Tab area.
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...