2
Measurement
128
Edge Pitch
FZ3 Processing Items List Manual
Setting item
Set value
[factory
default]
Description
Edge level
0 to 100
[50]
Specify a color changing level with which the edge is detected.
When the measurement result is lower than the actual number of
edges, specify a smaller value for the edge level.On the other hand,
when the measurement result is higher than the actual number of
edges, specify a larger value for the edge level.
Reference:
See "User's Manual", "Edge level" (p.304)
Edge color
level
0 to 442
[100]
Set the emphasis level for the edge color specified with [Edge color].
For monochrome cameras:
Important
●
Up to 1000 edges can be measured, but only a maximum of 256 can be displayed on the screen.
Setting item
Set value
[factory
default]
Description
Color to
count
●
[White]
●
Black
Select an edge color to be measured.
Mode
●
[Normal]
●
Precise
If the pin width or gap is less than 2 pixels, select precise.
Edge level
0 to 100
[50]
Specify the density change level to be detected as edges.
When the measurement result is lower than the actual number,
specify a smaller value for the edge level (or the minimum level).On
the other hand, when the measurement result is higher than the
actual number, specify a larger value for the edge level (or the
minimum level).
Reference:
See "User's Manual", "Edge level" (p.304)
3.
If necessary, set each item in the "Noise removal" area.
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...