
2
Measurement
216
Defect
FZ3 Processing Items List Manual
When the measurement results are unstable
Noise is detected as defects.
Parameter to be adjusted
Remedy
Measurement
Specify a larger value for "Defect judgement" in the judgement conditions.
Judgement will be NG.
Parameter to be
adjusted
Remedy
Measurement
Make the measurement region larger than the lower limit of the defect size.Or make the lower
limit of the defect detection size smaller than the measurement region.
When the processing speed is slow
Parameter to be
adjusted
Remedy
Measurement
Specify a larger value for the "Defect size".
Reduce the difference between the upper and lower limits of "Defect size".
Measurement Results for Which Output Is Possible (Defect)
The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Character
string
Description
Judgement
JG
Judgement result
Defect
F
Measured defect level
Position of defect
X
X Coordinate of measured defect position
Position of defect
Y
Y coordinate of measured defect position
Defect area
AR
The measured maximum defect area
Defect gravity
GX
The center of gravity X coordinates of the measured maximum defect area
Defect gravity
GY
The center of gravity Y coordinates of the measured maximum defect area
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...