2
Measurement
46
Search
FZ3 Processing Items List Manual
When PT is selected
Setting item
Set value
[factory
default]
Description
Angle range
[-180 to 180]
This item specifies the rotation angle range for searching.The normal
direction is clockwise.
Stability
1 to 5
[3]
If lowering stability does not speed up processing, it is likely that many
candidates have been detected.In this case, specify a larger value for
"Candidate LV" or "Stab."
Displaying/Re-Registering/Deleting a Model
If you save the model registration image, it is easy to re-register the model after model parameters are
changed.
Item
Description
Disp model/Input
image
The model image display and input image display are switched.
Re-register
When model parameters are modified, display the original model image and re-register the
model.
Delete
Deletes models.
Region Setting (Search)
Use a rectangle to specify the area where the model is searched.
Instead of measuring the entire input image, narrowing the measurement area shortens the processing
time.
1.
In the Item Tab area, tap [Region setting].
2.
Tap [Edit].
The figure setting area is displayed.
3.
Specify the area in which to search for the model.
The rectangle covering the entire screen is set. Adjust the size and position of the rectangle.
4.
Tap [OK].
The area to measure is registered.
Acesst 1.0 6251194
Содержание XPECTIA FZ3
Страница 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Страница 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Страница 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Страница 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Страница 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...