
1343
CJ-series Instruction Execution Times and Number of Steps
Section 4-2
4-2-29 Other Instructions
Note When a double-length operand is used, add 1 to the value shown in the length
column in the following table.
4-2-30 Block Programming Instructions
Instruction
Mne-
monic
Code
Length
(steps)
(See
note.)
ON execution time (
µ
s)
Condi-
tions
CPU6
@
H-R
CPU6
@
H
CPU4
@
H
CPU4
@
CJ1M
exclud-
ing
CPU11
/21
CJ1M
CPU11
/21
SET CARRY
STC
040
1
0.048
0.06
0.06
0.12
0.15
0.15
---
CLEAR CARRY
CLC
041
1
0.048
0.06
0.06
0.12
0.15
0.15
---
SELECT EM BANK
EMBC
281
2
14.0
14.0
15.1
15.1
---
---
---
EXTEND MAXIMUM
CYCLE TIME
WDT
094
2
15.0
15.0
19.7
19.7
23.6
22.0
---
SAVE CONDITION
FLAGS
CCS
282
1
8.6
8.6
12.5
---
14.2
12.9
---
LOAD CONDITION
FLAGS
CCL
283
1
9.8
9.8
13.9
---
16.3
15.7
---
CONVERT
ADDRESS FROM CV
FRMCV 284
3
13.6
13.6
19.9
---
23.1
31.8
---
CONVERT
ADDRESS TO CV
TOCV
285
3
11.9
11.9
17.2
---
22.5
31.4
---
DISABLE PERIPH-
ERAL SERVICING
IOSP
287
---
13.9
13.9
19.8
---
21.5
21.5
---
ENABLE PERIPH-
ERAL SERVICING
IORS
288
---
63.6
63.6
92.3
---
22.2
22.2
---
Instruction
Mne-
monic
Code
Length
(steps)
(See
note.)
ON execution time (
µ
s)
Conditions
CPU6
@
H-R
CPU6
@
H
CPU4
@
H
CPU4
@
CJ1M
exclud-
ing
CPU11
/21
CJ1M
CPU11
/21
BLOCK PRO-
GRAM BEGIN
BPRG
096
2
12.1
12.1
13.0
13.0
27.5
30.4
---
BLOCK PRO-
GRAM END
BEND
801
1
9.6
9.6
12.3
13.1
23.2
27.1
---
BLOCK PRO-
GRAM PAUSE
BPPS
811
2
10.6
10.6
12.3
14.9
16.0
21.7
---
BLOCK PRO-
GRAM
RESTART
BPRS
812
2
5.1
5.1
5.6
8.3
9.0
10.2
---
CONDITIONAL
BLOCK EXIT
(Execu-
tion condi-
tion) EXIT
806
1
10.0
10.0
11.3
12.9
23.8
26.0
EXIT condi-
tion satisfied
4.0
4.0
4.9
7.3
7.2
8.4
EXIT condi-
tion not satis-
fied
CONDITIONAL
BLOCK EXIT
EXIT (bit
address)
806
2
6.8
6.8
13.5
16.3
28.4
30.6
EXIT condi-
tion satisfied
4.7
4.7
7.2
10.7
11.4
13.1
EXIT condi-
tion not satis-
fied
Содержание SYSMAC CS Series
Страница 2: ......
Страница 4: ...iv ...
Страница 30: ...xxx ...
Страница 186: ...146 List of Instructions by Function Code Section 2 4 ...
Страница 194: ...154 3 35 4 MOVE BIT MOVBC 568 1273 3 35 5 BIT COUNTER BCNTC 621 1275 3 35 6 GET VARIABLE ID GETID 286 1277 ...
Страница 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Страница 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Страница 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Страница 1392: ...1352 ASCII Code Table Appendix A ...
Страница 1404: ...1364 Revision History ...