169
AR Area
Section 3-6
AR 16
00 to 10
Not used.
11
PC Setup Initialized Flag
Turns ON when a checksum error occurs in the PC Setup area and all settings are initialized back
to the default settings.
12
Program Invalid Flag
Turns ON when a checksum error occurs in the UM (user program) area, or when an improper
instruction is executed.
13
Instructions Table Initialized Flag
Turns ON when a checksum error occurs in the instructions table and all settings are initialized
back to the default settings.
14
Memory Cassette Added Flag
Turns ON if the Memory Cassette is installed while the power is on.
15
Memory Cassette Transfer Error Flag
Turns ON if a transfer cannot be successfully executed when DIP switch pin No. 2 is set to ON
(i.e., set to automatically transfer the contents of the Memory Cassette at power-up.)
AR 17
00 to 07
“Minutes” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
08 to 15
“Hour” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
AR 18
00 to 07
“Seconds” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
08 to 15
“Minutes” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
AR 19
00 to 07
“Hour” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
08 to 15
“Date” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
AR 20
00 to 07
“Month” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
08 to 15
“Year” portion of the present time, in 2 digits BCD
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
AR 21
00 to 07
“Day of week” portion of the present time, in 2 digits BCD [00: Sunday to 06: Saturday]
(Valid only when a Memory Cassette with a clock is installed. See page 170 for details.)
08 to 12
Not used.
13
30-second Adjustment Bit
Valid only when a Memory Cassette with a clock is installed. See page 170 for details.
14
Clock Stop Bit
Valid only when a Memory Cassette with a clock is installed. See page 170 for details.
15
Clock Set Bit
Valid only when a Memory Cassette with a clock is installed. See page 170 for details.
AR 22
00 to 07
Input Words
Number of words (2 digits BCD) allocated for input bits (Only a recognized value will be stored. A
value of 00 will be stored if an I/O UNIT OVER error has occurred.)
08 to 15
Output Words
Number of words (2 digits BCD) allocated for output bits (Only a recognized value will be stored. A
value of 00 will be stored if an I/O UNIT OVER error has occurred.)
AR 23
00 to 15
Power-off Counter
(4 digits BCD)
This is the count of the number of times that the power has been turned OFF. To clear the count,
write “0000” from a Programming Device.
Word
Bit(s)
Function
Содержание SYSMAC CQM1H Series
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ......
Страница 11: ......
Страница 15: ...xvi...
Страница 87: ...62 Calculating with Signed Binary Data Section 1 7...
Страница 169: ...144 Serial Communications Board Section 2 6...
Страница 537: ......
Страница 565: ......
Страница 569: ......
Страница 573: ......
Страница 577: ......