398
Special Instructions
Section 5-28
5-28-11 PULSE OUTPUT – PLS2(––)
Limitations
PLS2(––) cannot be used if the PC Setup (DM 6611) is set to high-speed
counter mode.
P must be 001 or 002 and D must be 000 or 001.
C to C+3 must be in the same data area.
Description
PLS2(––) can be used with the functions listed in the following table.
PLS2(––) is used to output a specified number of CW or CCW pulses from
port 1 or 2. The pulse output accelerates to the target frequency at a specified
rate and decelerates at the same rate. (Pulse output stops at 100 Hz.)
The following equations show how to calculate the approximate acceleration/
deceleration time T
1
and running time T
2
. Both times are in seconds.
Note
1.
Although T
1
and T
2
will vary slightly depending on the operating condi-
tions, the number of pulses output will be accurate.
2.
PLS2(––) will not operate if pulses are already being output from the spec-
ified port. Check the pulse output flags (AR 0515 for port 1 and AR 0615
for port 2) before executing PLS2(––).
3.
Refer to
1-5 Pulse Output Function
for more details.
P
:
Communications port
001 or 002
Ladder Symbols
Operand Data Areas
@PLS2(
−−
)
P
D
C
C
:
First control word
IR, SR, AR, DM, EM, HR, LR
D
:
Direction specifier
000 or 001
PLS2(
−−
)
P
D
C
Unit/Board
Function
Pulse I/O Board
Pulse outputs 1 and 2
(The mode for ports 1 and 2 must be set to the simple positioning
mode in DM 6611 of the PC Setup. PLS2(––) cannot be used if the
mode is set to high-speed counter mode.)
Target frequency
T
1
T
1
T
2
100 Hz
T
1
≅
0.0004
×
Acceleration/deceleration rate
Target frequency
T
2
≅
Number of pulses – (T
1
×
Target frequency)
Target frequency
Содержание SYSMAC CQM1H Series
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ......
Страница 11: ......
Страница 15: ...xvi...
Страница 87: ...62 Calculating with Signed Binary Data Section 1 7...
Страница 169: ...144 Serial Communications Board Section 2 6...
Страница 537: ......
Страница 565: ......
Страница 569: ......
Страница 573: ......
Страница 577: ......