![Omron SYSMAC C200H-NC112 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/omron/sysmac-c200h-nc112/sysmac-c200h-nc112_operation-manual_742431084.webp)
76
When the origin proximity signal is not needed, set DIP switch pin 3 to OFF
and use only the origin signal. Positioning will be carried out completely at
proximity speed (low speed).
Origin signal
Pulse output
1
0
CCW
CCW
CCW
CW limit (0.5 s pause)
CW
CW
ORIGIN SEARCH
(Start)
Origin (Stop)
ORIGIN SEARCH
(Start)
Origin (Stop)
ORIGIN SEARCH
(Start)
Origin (Stop)
Positioning axis
CW
Mode 1
Origin response time is 0.1 ms. Connect to pins A8 and B8 the Z-phase sig-
nal from an encoder receiving output from the servomotor driver. For wiring
diagrams in each mode, refer to
Section 2–2.
Note In this mode, even if origin proximity is set to absent, operation is performed
with origin proximity present.
Example 3:
No Origin Proximity Signal
ORIGIN SEARCH