Appendix G
Using the C200H-NC112 with CS1-series PCs
168
Program
MOV (021)
#0000
2002
MOV (021)
#1022
2003
MOV (021)
#0300
2004
MOV (021)
#0000
2002
MOV (021)
#0010
2003
MOV (021)
#0300
2004
SW2
a
b
a
b
200010
200010
c
200510
d
e
c
DIFU (013)
Turns ON “b” for one cycle with the rising edge of SW2.
Transfer
completion
Transfer Completed flag
200512
(word n+5, bit 12)
Busy flag
SW1
DIFU (013)
Turns ON “a” for one cycle with the rising edge of SW1.
(Transfers data from D00010 to D00012 to the PCU.)
200512
(word n+5, bit 12)
Busy flag
a
n+2
(Beginning transfer number)
n+3
(Beginning word number)
n+4
(PC data area and
number of transfers)
Position action #0 is speci-
fied as the destination.
D00010 is specified as the beginning
word of the data to be transferred.
The data in D00010 to D00012 is
specified as the data to be sent.
#0300
PC area: DM
No. of words: 3
n+2
(Beginning transfer number)
n+3
(Beginning word number)
n+4
(PC data area and
number of transfers)
Position action #0 is speci-
fied as the destination.
D20022 is specified as the beginning
word of the data to be transferred.
The data in D20022 to D20024 is
specified as the data to be sent.
#0300
PC area: DM
No. of words: 3
200010
TRANSFER DATA command bit
(word n, bit 10)
TRANSFER DATA command bit (word n, bit 10)
c
d
Transfer Completed flag
DIFU (013)
b