17
1. Zones with and without air conditioning not on the bridge or deck (e.g., boiler room)
2. Zones with and without air conditioning on the bridge (e.g., helm room)
3. Deck zone
4. Engine room zone (devices mounted on machinery that has strict vibration conditions,
such as diesel engines or air compressors)
5. Depends on the ship type. Emergency power supply devices on bulk carrier ships
carrying liquefied gas or hazardous chemicals.
•
Certification Zones for Shipping Standards
1. Not on deck or bridge
2. Bridge
Standard
No air
conditioning
Air
conditioning
No air
conditioning
Air
conditioning
3.
Deck
4.
Engine
(e.g.)
5. Ship type
(e.g., bulk ship
with liquefied
gas)
NK
No Yes No Yes
No
No
No
LR
No Yes No Yes
No
No
No
DNV
No Yes No No
No
No
No
RINA
No No No No
No
No
No
BV
No Yes No No
No
No
No
GL
No Yes No No
No
No
No
ABS
No Yes No No
No
No
No
KR
No Yes No No
No
No
No
CR
No No No No
No
No
No
•
Precautions for Compliance with Shipping Standards
1. Always install the NS-series PT in a control panel.
2. Install the NS-series PT in a control panel that has air conditioning.
3. Cover the entire surface of the NS-series PT with electromagnetic shielding material and
ground the control panel or operation panel with copper tape or other conductive tape.
4. Completely shield the gap at openings in the control panel or operation panel with a
gasket.
5. Completely shield the gap between the NS-series PT and the panel cutout with copper
tape or other conductive tape before securing the NS-series PT with the mounting
bracket.
6.
Connect a noise filter to the power supply line connected between the 24-VDC and
0-VDC terminals.
Electromagnetic Shielding
Manufacturer
Seiwa Electric Mfg. Co. Ltd.
Model E09F-100,
E09R13502P
Note: The transmission rate of the liquid crystal display will decrease by approximately
50% when the electromagnetic shielding is mounted.
Noise Filter
Manufacturer
Cosel Co. Ltd.
Model TAH-06-683
Содержание NS15-V2 Series
Страница 1: ...Cat No V083 E1 14 Programmable Terminals NS Series SETUP MANUAL...
Страница 2: ......
Страница 34: ...1 4 Procedure for Running NS series PTs 1 12...
Страница 54: ...2 2 Part Names and Functions 2 20...
Страница 144: ...4 4 Recommended Connector Cables 4 28...
Страница 174: ...5 3 Connecting to Host via EtherNet IP 5 30...
Страница 196: ...6 3 PT Settings 6 22 PT Tab Page for the NS10 and NS8 Page 1 Page 2 Page 3 Page 4 PT Tab Page for the NS5 Page 1 Page 2...
Страница 246: ...6 11 Verifying Tags 6 72...
Страница 280: ...Appendix 2 Dimensions A 20 NS5 V1 V2 Cable Connection Dimensions...
Страница 333: ......
Страница 334: ......