74
CX-Programmer Procedures
Section 4-12
7.
The following display will appear when the data link table settings have
been made for all nodes. The example shows node 1 selected.
Settings and Display
Contents
Item
Contents
Common
Link:
Com-
mon link
parameters
Cycle Time:
Communications cycle
time
Data link communications cycle time:
Select automatic or manual settings. Man-
ual setting range: 5 to 255 ms.
Target
Node
Total link CH:
Total number of
link words
Displays the total number of data link
words (CIO Area + DM Area). In the exam-
ple, CIO 70 words + DM 90 words = 160
words.
Nodes
The number of send words is displayed for
each node. CIO: Number of CIO Area send
words. DM: Number of DM Area send
words. In the example, CIO: 20 send
words, DM: 30 send words.
Node Information
Start Channel:
Start words
Displays the words from which data links
start in the CIO and DM Areas for the
selected node. In the example, CIO 1000
and D00500 are displayed as the start
addresses.
Refresh
Parameters
Displays the order in which nodes are
refreshed in the second column from the
left. The values on the right are the number
of words received from the node in the CIO
Area and DM Area.
In this example, nodes are refreshed in the
order 1, 3, 2.
Содержание CS1W-SLK11-21 - 06-2004
Страница 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Страница 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ......
Страница 11: ......
Страница 17: ......
Страница 49: ......
Страница 107: ......
Страница 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Страница 143: ......
Страница 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Страница 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Страница 177: ......
Страница 179: ......
Страница 195: ......
Страница 199: ......
Страница 201: ...Authorized Distributor Cat No W367 E1 02 Note Specifications subject to change without notice Printed in Japan...
Страница 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...