4
SYSMAC LINK Unit Features
Section 1-2
1-2-1
Standard Models
SYSMAC LINK Units
SYSMAC LINK Programming Devices
1-2-2
Specifications
General Specifications
Conform to the specifications of the CS Series.
SYSMAC LINK Unit Specifications
Applicable
PLCs
Unit
classification
Name
Transmission
path
Communications
Model
CS-series
PLCs
(CS1-H, CS1)
CPU Bus Unit
Coaxial SYSMAC
LINK Unit
Coaxial cable
Data links (manually set or auto-
matically set), messages (through
SEND(90), RECV(98), and
CMND(490) instructions)
CS1W-SLK21
Optical SYSMAC
LINK Unit
Optical fiber
cable
CS1W-SLK11
Product
Specifications
Model
CX-Net (within CX-Pro-
grammer)
Setting manually set data links, starting/stopping data links, reading
network status, reading error logs, setting routing tables, testing net-
works, changing network parameters settings
Note
The CS-series SYSMAC LINK Unit cannot be directly con-
nected to SYSMAC Support Software.
WS02-CX
@@
E
Item
Specifications
Model
CS1W-SLK21
CS1W-SLK11
Type
Coaxial
Optical fiber
Unit classification
CS-series CPU Bus Unit
Applicable PLCs
CS-series PLCs
Max. number of Units
4 Units max. (total Coaxial Units and Optical Units)
Mounting position
Four slots on the CPU Racks and CS-series Expansion Racks
Allowable unit number settings
0 to F
CPU Unit data
exchange areas
CPU Bus Unit
Area
25 words/Unit
SYSMAC Link Unit to CPU Unit:
Data link status, network participation status, error information, etc.
Words allo-
cated to CPU
Bus Units in
DM Area
100 words/Unit (Only first word of the 100 words is used.)
CPU Unit to SYSMAC LINK Unit:
Polling/polled node setting, starting data links, data link mode (automatic/manual) set-
tings, number of data link words for automatic data links, etc.
Settings
Rotary switch:
Unit number
Rotary switches: Node addresses
Indicators
LEDs: 9 on Optical Unit, 8 on Coaxial Unit
Coaxial and Optical Units:
Running, communications error, CPU Unit error, network participation, polling, send,
receive, data link active
Optical Unit Only: Power ON
Front panel connectors
BNC connector
Two optical fiber connectors
Power supply terminal block (24 V DC)
Effect on CPU Unit cycle time
0.2 ms
Requires an additional 1.5 ms + (No. of words transferred x 0.001 ms) when data links
are used.
Requires additional event processing time when servicing messages.
Current consumption (supplied
from Power Supply Unit)
480 mA at 5 V DC
470 mA at 5 V DC
Dimensions
35
×
130
×
101 mm (W x H x D)
Содержание CS1W-SLK11-21 - 06-2004
Страница 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Страница 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ......
Страница 11: ......
Страница 17: ......
Страница 49: ......
Страница 107: ......
Страница 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Страница 143: ......
Страница 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Страница 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Страница 177: ......
Страница 179: ......
Страница 195: ......
Страница 199: ......
Страница 201: ...Authorized Distributor Cat No W367 E1 02 Note Specifications subject to change without notice Printed in Japan...
Страница 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...