8
Programming Devices and Support Software
Section 1-4
Routing Tables (See page 86)
Routing tables are set using the Support Software to specify paths for sending
and receiving data between networks. The routing tables consist of the follow-
ing two tables.
• Local Network Table: Set the combination of unit numbers and network
addresses for each Communications Unit.
• Relay Network Table: Set the communications path between the sender
and receiver.
1-3-4
Message Service
The SYSMAC LINK Units support SEND(90) and RECV(98) instructions for
reading data from and writing data to other node PLCs. The SYSMAC LINK
Units also support CMND(490) instructions for sending and receiving FINS
commands that control PLCs and CPU Bus Units. Using these instructions, it
is possible to control complicated functions without creating a communica-
tions program.
Refer to
SECTION 6 Message Service
for details.
1-3-5
Remote Programming and Monitoring
Remote programming and monitoring can be performed between SYSMAC
LINK, Controller Link, and Ethernet Networks. A maximum of three levels of
network communications (including the local network) are supported.
Refer to
SECTION 7 Remote Monitoring and Programming
for details.
1-3-6
RAS Functions
The SYSMAC LINK Unit supports RAS functions to help protect the network
and recover from errors.
Internode Test
Communications between the local node and a specified node within the net-
work can be tested. The test settings are made using the Support Software.
Broadcast Test
All the nodes within a specified network can be tested using the Support Soft-
ware broadcast test function.
Error Log
(See page 137)
If an error occurs in the Unit, the time of the error and the error contents are
logged in EEPROM within the Unit. The logged error information can be read
using the Support Software.
Polling Node Backup
(See page 143)
If an error occurs in the polling node, the Unit at another node automatically
becomes the polling node and rebuilds the network.
Node Bypass
(See page 143)
If a backup power supply is used with an Optical SYSMAC LINK System, any
node that goes down will be automatically bypassed, preventing the entire
network from going down.
1-4
Programming Devices and Support Software
The CX-Programmer is needed to use a SYSMAC LINK Network.
Содержание CS1W-SLK11-21 - 06-2004
Страница 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Страница 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ......
Страница 11: ......
Страница 17: ......
Страница 49: ......
Страница 107: ......
Страница 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Страница 143: ......
Страница 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Страница 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Страница 177: ......
Страница 179: ......
Страница 195: ......
Страница 199: ......
Страница 201: ...Authorized Distributor Cat No W367 E1 02 Note Specifications subject to change without notice Printed in Japan...
Страница 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...