SECTION 3
Part
Na
m
e
s
and
F
unct
ions
SECTION 3
CJ-series ID Sensor Units
55
RFID System
User's Manual
Indicators
The indicators show the operating status of the Unit. The relationship between the indicator status and
the Unit status is shown in the following table.
Unit Number Switches
Data exchange between the CPU Unit and ID Sensor Unit is performed using words allocated to the
Unit in the Special I/O Unit Area and in the Special I/O Unit words in the DM Area. The words allocated
to the ID Sensor Unit in these two areas are determined by the setting of the unit number switches on
the Unit’s front panel.
Indicator
Name
Color
Meaning
RUN
RUN
Green
Lit
The ID Sensor Unit is operating normally.
Not lit
The ID Sensor Unit is stopped.
ERC
(Error in Controller)
Unit error
Red
Lit
An error has occurred in the ID Sensor Unit.
Not lit
No error has occurred in the ID Sensor Unit.
ERH
(Error at CPU Unit)
CPU Unit error
Red
Lit
An error has occurred in the CPU Unit.
Not lit
No error has occurred in the CPU Unit.
ERP
(Antenna Power Error)
Antenna power
error
Red
Lit
An error has occurred in the power supply to the Antenna.
Not lit
The power supply to the Antenna is normal.
HEAD1
(Antenna
1)
T/R
Communicating
Yellow
Lit
Communications are active.
Not lit
Communications not being performed with the RF Tag.
NORM/ERR
Normal end
Green
Lit
Communications with the RF Tag ended normally.
Not lit
The indicator is not Iit in all other cases.
Error end
Red
Lit
Communications with the RF Tag ended in an error.
Not lit
The indicator is not Iit in all other cases.
HEAD2
(Antenna
2)
T/R
Communicating
Yellow
Lit
Communications are active.
Not lit
Communications not being performed with the RF Tag.
NORM/ERR
Normal end
Green
Lit
Communications with the RF Tag ended normally.
Not lit
The indicator is not Iit in all other cases.
Error end
Red
Lit
Communications with the RF Tag ended in an error.
Not lit
The indicator is not Iit in all other cases.
CJ1W-V680C11
CJ1W-V680C12
Switch
No.
Unit
No.
Words allocated in
Special I/O Unit
Area
Words allocated
in DM Area
Words allocated in
Special I/O Unit
Area
Words allocated
in DM Area
0
Unit 0
CIO 2000 to
CIO 2009
D20000 to D20099
CIO 2000 to
CIO 2019
D20000 to D20199
1
Unit 1
CIO 2010 to
CIO 2019
D20100 to D20199
CIO 2010 to
CIO 2029
D20100 to D20299
:
:
:
:
:
:
94
Unit 94
CIO 2940 to
CIO 2949
D29400 to D29499
CIO 2940 to
CIO 2959
D29400 to D29599
95
Unit 95
CIO 2950 to
CIO 2959
D29500 to D29599
(Cannot be set)
0
1 2 3
4
5
6
7
8
9
0
1 2 3
4
5
6
7
8
9
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...
Страница 213: ......