![background image](http://html1.mh-extra.com/html/omron/cj1w-v680c11/cj1w-v680c11_user-manual_743942027.webp)
SECTIO
N
1
Sys
te
m
Conf
igura
tion
SECTION 1
Features and System Configuration
25
RFID System
User's Manual
CJ-series PLCs
ID Sensor Units are connected as I/O Units in the system configuration, as shown below.
Use the following procedure to connect an ID Sensor Unit.
1.
Align the connectors and press in firmly on the Units to connect them completely.
2.
Move the yellow sliders on the top and bottom of the Unit to the lock position to secure the Units. The
sliders should click into place.
3.
Attach an End Cover to the Unit on the right end of the Rack.
The CJ-series PLC may not operate properly if the sliders are not locked firmly into place.
Power Supply Unit
End Cover
(included with CPU Unit)
CPU Unit
ID Sensor Units
Hook
Connector
Hook holes
Move the sliders to the back
until they click into place.