SECTION 6
Controlling the ID Sensor Unit
131
RFID System
User's Manual
• The bits that are turned ON in the data set for the Command Option will be masked and will not be changed. Write
data will be written to the data storage area for bits that are OFF in the write data.
• Verification will not be performed if No Verification is set for writing.
• Check the memory capacity of the RF Tag before setting the Processing Address and Number of Processing Bytes. If
the Processing Address and Number of Processing Bytes are not suitable for the RF Tag for which communications
are being performed, the RF Tag Address Error Flag (CIO n+8, bit 13) will turn ON.
• The mask data is always specified leftmost to rightmost regardless of the processing specification.