SECTIO
N
8
Sample Pro
g
ramming
SECTION 8
Appendices
179
RFID System
User's Manual
• Timing Chart (CIO n = CIO 2000 + (10 x 0) = CIO 2000)
• If communications with the RF Tag fail or an error occurs, communications will be aborted at that
point, the error flags in the Results Information (CIO n+8) will turn ON accordingly, and the error code
will be placed in the Processing Results Monitor (CIO n+9). The previous read data will not be
changed.
• To confirm the execution results from the user program, use the ON status of the Normal End Flag or
Error End Flag in the Unit Status.
• Do not turn ON the Command Execution Bit during command execution (i.e., while the ID Busy Flag
is ON). It will be ignored.
Missing error
Command Exec
u
tion Bit
CIO n,
b
it 00
Command
CIO n+1 to n+4
Error End
CIO n+7,
b
it 02
ID B
u
sy
CIO n+7,
b
it 00
Res
u
lts Information
CIO n+
8
Data storage area
N
ormal End
CIO n+7,
b
it 01
1 scan
Read
Read data
0000
Comm
u
nications
processing
Read
0000
W
aiting for
RF Tag
1 scan
Res
u
lts Information
stored.
Содержание CJ1W-V680C11
Страница 62: ...60 SECTION 3 Connections and Wiring RFID System User s Manual SECTION 3 CJ series ID Sensor Units MEMO...
Страница 78: ...76 SECTION 4 I O Data Allocations RFID System User s Manual SECTION 4 Data Exchange with the CPU Unit MEMO...
Страница 118: ...116 SECTION 5 RF Tag Memory Error Correction RFID System User s Manual SECTION 5 ID Sensor Unit Functions MEMO...
Страница 158: ...156 SECTION 7 Troubleshooting RFID System User s Manual SECTION 7 Troubleshooting Alarms and Errors MEMO...
Страница 213: ......